Publication: Effect of cement film thickness on shear bond strengths of two resin cements.
dc.contributor.author | Somchai Urapepon | en_US |
dc.contributor.author | สมชาย อุรพีพล | en_US |
dc.contributor.author | Wutipong Luesak | en_US |
dc.contributor.author | Chatcharee Suchatlampong | en_US |
dc.contributor.author | ชัชรี สุชาติล้ําพงศ์ | en_US |
dc.contributor.correspondence | Somchai Urapepon | en_US |
dc.contributor.correspondence | สมชาย อุรพีพล | en_US |
dc.contributor.other | Mahidol University. Faculty of Dentistry. Department of Prosthodontics | en_US |
dc.date.accessioned | 2015-01-27T10:24:30Z | |
dc.date.accessioned | 2017-01-10T01:58:46Z | |
dc.date.available | 2015-01-27T10:24:30Z | |
dc.date.available | 2017-01-10T01:58:46Z | |
dc.date.created | 2015-01-06 | |
dc.date.issued | 2014-05 | |
dc.description.abstract | Objective: The purpose of this study was to determine the effect of cement thickness on the shear bond strength of two commercial adhesive resin cements, Panavia-F and Super-Bond C&B when used to bond nickel-chromium alloy to bovine dentine. Materials and methods: Ni-Cr alloy discs, Ø5x3 mm and bovine teeth (120 pairs) were bonded together by two different resin cements (Super Bond C&B and Panavia F) at four different film thicknesses (50, 100, 150 and 200 micrometers). After bonding, they were stored in 37°C water for 24 h. Shear bond test at a crosshead speed of 0.5mm/min was performed. The fracture surfaces of the specimens were observed by scanning electron microscope. Results: Panavia F showed the shear bond strength ranged from 4.02±1.44 MPa to 9.32±2.40 MPa, whereas Super Bond C&B showed a shear bond strength ranging from 5.01±1.38 MPa to 7.10±2.70 MPa. Both cements showed maximum shear bond strength to Ni-Cr alloy at 100 micrometers. In general, Panavia F showed higher bond strength than Super Bond C&B. Both cement thickness and cement type, and their interaction were found to have an effect on the shear bond strength of nickel-chromium alloy to bovine dentine. No significant differences were found when the film thickness was less than 150 micrometers for Panavia F (P>0.05) while those of Super Bond C&B were not significantly different at any film thickness (P>0.05). When the thickness of cement increased, more voids in the cement were found especially in Super Bond C&B. Conclusions: Within the limitations of this study, the shear bond strength between 50 and 150 micrometers was not significantly affected by the cement thickness. | en_US |
dc.identifier.citation | Urapepon S, Luesak W, Suchatlampong C. Effect of cement film thickness on shear bond strengths of two resin cements. M Dent J. 2014; 34(2): 122-8. | en_US |
dc.identifier.issn | 0125-5614 (printed) | |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/123456789/1155 | |
dc.language.iso | eng | en_US |
dc.rights | Mahidol University | en_US |
dc.rights.holder | Mahidol University | en_US |
dc.subject | Panavia | en_US |
dc.subject | Super bond | en_US |
dc.subject | Film thickness | en_US |
dc.subject | Ni-Cr alloy | en_US |
dc.subject | Shear bond strength | en_US |
dc.subject | Resin cement bovine dentine | en_US |
dc.subject | Open Access article | en_US |
dc.subject | วิทยาสารทันตแพทยศาสตร์มหิดล | |
dc.subject | Mahidol Dental Journal | |
dc.title | Effect of cement film thickness on shear bond strengths of two resin cements. | en_US |
dc.type | Article | en_US |
dcterms.dateAccepted | 2014-01-02 | |
dspace.entity.type | Publication | |
mods.location.url | http://www.dt.mahidol.ac.th/division/offeducation/education_1_6/wittayasarn/2-57/%E0%B9%80%E0%B8%A3%E0%B8%B7%E0%B9%88%E0%B8%AD%E0%B8%87%E0%B8%97%E0%B8%B5%E0%B9%88%203.pdf |