Publication:
Single tube multiplex real-time PCR for the rapid detection of herpesvirus infections of the central nervous system

dc.contributor.authorNipaporn Sankuntawen_US
dc.contributor.authorSaovaluk Sukpraserten_US
dc.contributor.authorChulapan Engchanilen_US
dc.contributor.authorWanlop Kaewkesen_US
dc.contributor.authorWasun Chantratitaen_US
dc.contributor.authorVantanit Pairojen_US
dc.contributor.authorViraphong Lulitanonden_US
dc.contributor.otherKhon Kaen Universityen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-05-03T08:03:11Z
dc.date.available2018-05-03T08:03:11Z
dc.date.issued2011-04-01en_US
dc.description.abstractHuman herpesvirus infection of immunocompromised hosts may lead to central nervous system (CNS) infection and diseases. In this study, a single tube multiplex real-time PCR was developed for the detection of five herpesviruses (HSV-1, HSV-2, VZV, EBV and CMV) in clinical cerebrospinal fluid (CSF) specimens. Two primer pairs specific for the herpesvirus polymerase gene and five hybridization probe pairs for the specific identification of the herpesvirus types were used in a LightCycler multiplex real-time PCR. A singleplex real-time PCR was first optimized and then applied to the multiplex real-time PCR. The singleplex and multiplex real-time PCRs showed no cross-reactivity. The sensitivity of the singleplex real-time PCR was 1 copy per reaction for each herpesvirus, while that of the multiplex real-time PCR was 1 copy per reaction for HSV-1 and VZV and 10 copies per reaction for HSV-2, EBV and CMV. Intra and inter-assay variations of the single tube multiplex assay were in the range of 0.02%-3.67% and 0.79%-4.35%, respectively. The assay was evaluated by testing 62 clinical CSF samples and was found to have equivalent sensitivity, specificity and agreement as the routine real-time PCR, but reducing time, cost and amount of used sample. © 2011 Elsevier Ltd.en_US
dc.identifier.citationMolecular and Cellular Probes. Vol.25, No.2-3 (2011), 114-120en_US
dc.identifier.doi10.1016/j.mcp.2011.03.004en_US
dc.identifier.issn08908508en_US
dc.identifier.other2-s2.0-79955452214en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/11568
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79955452214&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.titleSingle tube multiplex real-time PCR for the rapid detection of herpesvirus infections of the central nervous systemen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79955452214&origin=inwarden_US

Files

Collections