Publication:
Impact of endobroncial ultrasound guided transbrocnhial needle aspiration on clinical practice guideline.

dc.contributor.authorJamsak Tscheikunaen_US
dc.contributor.authorSupparerk Disayabutren_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-06-11T05:16:27Z
dc.date.available2018-06-11T05:16:27Z
dc.date.issued2012-02-01en_US
dc.description.abstractEndobronchial ultrasound guided transbronchial needle aspiration (EBUS TBNA) is performed by using special bronchoscope which has an ultrasound probe at its tip that could demonstrate lymph node outside the airway and allow for real time observation of transbronchial needle aspiration. The sensitivity and specificity of EBUS TBNA are high in many studies. However because of the high expense and special training required, the impact of this method on clinical practice guidelines (CPG) needs to be further evaluated. The patients were classified to three groups. Group One included proven lung cancer patients who do not have distant metastasis and no mediastinal lymphadenopathy as demonstrated by computer tomography. Group Two was the same as group One except there was evidence of mediastinal lymphadenopathy. The Third Group included patients who only had mediastinal lymphadenopathy without lung lesion. All lymph node stations were examined by EBUS and their sizes were recorded. Selected puncture of a lymph node was done and tissue was sent for cytological examination. There was no rapid on site cytologic examination. The impact on CPG was calculated from the number of patients who be prevented from mediastinoacopy. There were 158 patients in the present study. The number of patients in group 1, 2 and 3 were 64, 57 and 37 respectively. The mean size of the mediastinal lymph node which detected by EBUS was 1.34 cm (range 0.36-3.81 cm). TBNAs were done in 164 nodes out of 353 nodes found by EBUS. The most common enlarged mediastinal node was at station 7 and those at station 4R and 3 were less common in sequence. In all three groups, malignant cells were established in 71 patients (44.9%). In group 1 malignancy was found in 21 (32.8%), in 39 patients (68.4%) in group 2 and in 11 patients (29.7%) in group 3. If the CPG recommend mediastinoscopy for all lung cancer patients, EBUS TBNA can save 49.5% of patients from the procedure. But if only enlarged mediastinal node would be considered for mediastinoscopy, EBUS TBNA can save up to 59.5% patients from mediastinal surgery. EBUS TBNA has impact on CPG for assessment of mediastinal node in lung cancer and mediastinal lymphadenopathy patients.en_US
dc.identifier.citationJournal of the Medical Association of Thailand = Chotmaihet thangphaet. Vol.95 Suppl 2, (2012)en_US
dc.identifier.issn01252208en_US
dc.identifier.other2-s2.0-84862289557en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/14962
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84862289557&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleImpact of endobroncial ultrasound guided transbrocnhial needle aspiration on clinical practice guideline.en_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84862289557&origin=inwarden_US

Files

Collections