Publication:
Cardiothoracic ratio measurement using artificial intelligence: observer and method validation studies

dc.contributor.authorPairash Saiviroonpornen_US
dc.contributor.authorKanchanaporn Rodbangyangen_US
dc.contributor.authorTrongtum Tongdeeen_US
dc.contributor.authorWarasinee Chaisangmongkonen_US
dc.contributor.authorPakorn Yodpromen_US
dc.contributor.authorThanogchai Siriapisithen_US
dc.contributor.authorSuwimon Wonglaksanapimonen_US
dc.contributor.authorPhakphoom Thiraviten_US
dc.contributor.otherSiriraj Hospitalen_US
dc.contributor.otherKing Mongkut's University of Technology Thonburien_US
dc.date.accessioned2022-08-04T09:03:42Z
dc.date.available2022-08-04T09:03:42Z
dc.date.issued2021-12-01en_US
dc.description.abstractBackground: Artificial Intelligence (AI) is a promising tool for cardiothoracic ratio (CTR) measurement that has been technically validated but not clinically evaluated on a large dataset. We observed and validated AI and manual methods for CTR measurement using a large dataset and investigated the clinical utility of the AI method. Methods: Five thousand normal chest x-rays and 2,517 images with cardiomegaly and CTR values, were analyzed using manual, AI-assisted, and AI-only methods. AI-only methods obtained CTR values from a VGG-16 U-Net model. An in-house software was used to aid the manual and AI-assisted measurements and to record operating time. Intra and inter-observer experiments were performed on manual and AI-assisted methods and the averages were used in a method variation study. AI outcomes were graded in the AI-assisted method as excellent (accepted by both users independently), good (required adjustment), and poor (failed outcome). Bland–Altman plot with coefficient of variation (CV), and coefficient of determination (R-squared) were used to evaluate agreement and correlation between measurements. Finally, the performance of a cardiomegaly classification test was evaluated using a CTR cutoff at the standard (0.5), optimum, and maximum sensitivity. Results: Manual CTR measurements on cardiomegaly data were comparable to previous radiologist reports (CV of 2.13% vs 2.04%). The observer and method variations from the AI-only method were about three times higher than from the manual method (CV of 5.78% vs 2.13%). AI assistance resulted in 40% excellent, 56% good, and 4% poor grading. AI assistance significantly improved agreement on inter-observer measurement compared to manual methods (CV; bias: 1.72%; − 0.61% vs 2.13%; − 1.62%) and was faster to perform (2.2 ± 2.4 secs vs 10.6 ± 1.5 secs). The R-squared and classification-test were not reliable indicators to verify that the AI-only method could replace manual operation. Conclusions: AI alone is not yet suitable to replace manual operations due to its high variation, but it is useful to assist the radiologist because it can reduce observer variation and operation time. Agreement of measurement should be used to compare AI and manual methods, rather than R-square or classification performance tests.en_US
dc.identifier.citationBMC Medical Imaging. Vol.21, No.1 (2021)en_US
dc.identifier.doi10.1186/s12880-021-00625-0en_US
dc.identifier.issn14712342en_US
dc.identifier.other2-s2.0-85107587945en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/77572
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85107587945&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleCardiothoracic ratio measurement using artificial intelligence: observer and method validation studiesen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85107587945&origin=inwarden_US

Files

Collections