Publication:
Corrected lymphocyte percentages reduce the differences in absolute CD4+T lymphocyte counts between dual-platform and single-platform flow cytometric approaches

dc.contributor.authorEgarit Noulsrien_US
dc.contributor.authorDinar Abudayaen_US
dc.contributor.authorSurada Lerdwanaen_US
dc.contributor.authorKovit Pattanapanyasaten_US
dc.contributor.otherFaculty of Medicine, Siriraj Hospital, Mahidol Universityen_US
dc.date.accessioned2019-08-23T10:29:54Z
dc.date.available2019-08-23T10:29:54Z
dc.date.issued2018-08-01en_US
dc.description.abstract© American Society for Clinical Pathology 2018. All rights reserved. Objective: To determine whether a corrected lymphocyte percentage could reduce bias in the absolute cluster of differentiation (CD)4+ T lymphocyte counts obtained via dual-platform (DP) vs standard single-platform (SP) flow cytometry. Methods: The correction factor (CF) for the lymphocyte percentages was calculated at 6 laboratories. The absolute CD4+ T lymphocyte counts in 300 blood specimens infected with human immunodeficiency virus (HIV) were determined using the DP and SP methods. Results: Applying the CFs revealed that 4 sites showed a decrease in the mean bias of absolute CD4+ T lymphocyte counts determined via DP vs standard SP (−109 vs −84 cells/μL, −80 vs −58 cells/μL, −52 vs −45 cells/μL, and −32 vs 1 cells/μL). However, 2 participating laboratories revealed an increase in the difference of the mean bias (−42 vs −49 cells/μL and −20 vs −69 cells/μL). Conclusions: Use of the corrected lymphocyte percentage shows potential for decreasing the difference in CD4 counts between DP and the standard SP method.en_US
dc.identifier.citationLab Medicine. Vol.49, No.3 (2018), 246-253en_US
dc.identifier.doi10.1093/labmed/lmy002en_US
dc.identifier.issn19437730en_US
dc.identifier.issn00075027en_US
dc.identifier.other2-s2.0-85055160563en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/45091
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85055160563&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectMedicineen_US
dc.titleCorrected lymphocyte percentages reduce the differences in absolute CD4+T lymphocyte counts between dual-platform and single-platform flow cytometric approachesen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85055160563&origin=inwarden_US

Files

Collections