Publication:
Sequential injection system for simultaneous determination of sucrose and phosphate in cola drinks using paired emitter-detector diode sensor

dc.contributor.authorPhoonthawee Saetearen_US
dc.contributor.authorKittiwut Khamtauen_US
dc.contributor.authorNuanlaor Ratanawimarnwongen_US
dc.contributor.authorKamonthip Sereenonchaien_US
dc.contributor.authorDuangjai Nacaprichaen_US
dc.contributor.otherFlow Innovation-Research for Science and Technology Laboratories (FIRST Labs.en_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherSrinakharinwirot Universityen_US
dc.contributor.otherThammasat Universityen_US
dc.date.accessioned2018-10-19T04:47:57Z
dc.date.available2018-10-19T04:47:57Z
dc.date.issued2013-06-24en_US
dc.description.abstractThis work presents the simultaneous determination of sucrose and phosphate by using sequential injection (SI) system with a low cost paired emitter-detector diode (PEDD) light sensor. The PEDD uses two 890 nm LEDs. Measurement of sucrose in Brix unit was carried out based on the detection of light refraction occurring at the liquid interface (the schlieren effect) between the sucrose solution and water. Phosphate was measured from the formation of calcium phosphate with turbidimetric detection. With careful design of the loading sequence and volume (sample - precipitating reagent - sample), simultaneous detection of sucrose and phosphate was accomplished with the single PEDD detector. At the optimized condition, linear calibrations from 1 to 7 Brix sucrose and from 50 to 200 mg PO43-L-1were obtained. Good precision at lower than 2% RSD (n=10) for both analytes with satisfactory throughput of 21 injections h-1was achieved. The method was successfully applied for the determination of sucrose and phosphate in cola drinks. The proposed method is readily applicable for automation and is found to be an alternative method to conventional procedures for on-line quality control process in cola drink industry. © 2013 Published by Elsevier B.V.All rights reserved.en_US
dc.identifier.citationTalanta. Vol.115, (2013), 361-366en_US
dc.identifier.doi10.1016/j.talanta.2013.05.051en_US
dc.identifier.issn00399140en_US
dc.identifier.other2-s2.0-84879108107en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/31527
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84879108107&origin=inwarden_US
dc.subjectChemistryen_US
dc.titleSequential injection system for simultaneous determination of sucrose and phosphate in cola drinks using paired emitter-detector diode sensoren_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84879108107&origin=inwarden_US