Publication:
A new Standard Uptake Values (SUV) calculation based on pixel intensity values

dc.contributor.authorSomphob Soongsathitanonen_US
dc.contributor.authorPawitra Masa-Ahen_US
dc.contributor.authorMalulee Tuntawiroonen_US
dc.contributor.otherThammasat Universityen_US
dc.contributor.otherCoventry Universityen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherThaksin Universityen_US
dc.contributor.otherFaculty of Medicine, Siriraj Hospital, Mahidol Universityen_US
dc.contributor.otherUniversity of Texas MD Anderson Cancer Centeren_US
dc.date.accessioned2018-06-11T04:45:38Z
dc.date.available2018-06-11T04:45:38Z
dc.date.issued2012-02-27en_US
dc.description.abstractPositron Emission Tomography (PET) is one of the major cancer imaging tools for both diagnosis and staging. The prognostic significant parameter for PET scan is Standard Uptake Values (SUV). The SUV can be used as a tool to supplement the visual interpretation for physician. However the SUV can not be calculated without the vendor's application software. In order to calculate the SUV without the vendor's application software, a new standard uptake values (SUV) calculation scheme based on image intensity has been introduced. This new scheme is tested by using 108 slices of DICOM files obtained from 11 patients (8 men, 3 women). The comparative study between this scheme and the GE Xeleris workstation has been done and the results showed that the correlation between the two systems is statistically significant with a 99% confidence interval. The average percentage of accuracy is 85% for the report at a 95% confidence interval. So this scheme can be used as an alternative tool to calculate the SUV and it can be installed in any computers.en_US
dc.identifier.citationInternational Journal of Mathematics and Computers in Simulation. Vol.6, No.1 (2012), 26-33en_US
dc.identifier.issn19980159en_US
dc.identifier.other2-s2.0-84857241683en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/14052
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84857241683&origin=inwarden_US
dc.subjectComputer Scienceen_US
dc.subjectMathematicsen_US
dc.titleA new Standard Uptake Values (SUV) calculation based on pixel intensity valuesen_US