Publication:
Comparison of three non-invasive hemodynamic monitoring methods in critically ill children

dc.contributor.authorChanapai Chaiyakulsilen_US
dc.contributor.authorMarut Chantraen_US
dc.contributor.authorPoomiporn Katanyuwongen_US
dc.contributor.authorAnant Khositsethen_US
dc.contributor.authorNattachai Anantasiten_US
dc.contributor.otherFaculty of Medicine, Ramathibodi Hospital, Mahidol Universityen_US
dc.date.accessioned2019-08-23T10:16:41Z
dc.date.available2019-08-23T10:16:41Z
dc.date.issued2018-06-01en_US
dc.description.abstract© 2018 Chaiyakulsil et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Introduction Hemodynamic parameters measurements were widely conducted using pulmonary artery catheter (PAC) with thermodilution as a reference standard. Due to its technical difficulties in children, transthoracic echocardiography (TTE) has been widely employed instead. Nonetheless, TTE requires expertise and is time-consuming. Noninvasive cardiac output monitoring such as ultrasonic cardiac output monitor (USCOM) and electrical velocimetry (EV) can be performed rapidly with less expertise requirement. Presently, there are inconsistent evidences, variable precision, and reproducibility of EV, USCOM and TTE measurements. Our objective was to compare USCOM, EV and TTE in hemodynamic measurements in critically ill children. Materials and methods This was a single center, prospective observational study in critically ill children. Children with congenital heart diseases and unstable hemodynamics were excluded. Simultaneous measurements of hemodynamic parameters were conducted using USCOM, EV, and TTE. Inter-rater reliability was determined. Bland-Altman plots were used to analyse agreement of assessed parameters. Results Analysis was performed in 121 patients with mean age of 4.9 years old and 56.2% of male population. Interrater reliability showed acceptable agreement in all measured parameters (stroke volume (SV), cardiac output (CO), velocity time integral (VTI), inotropy (INO), flow time corrected (FTC), aortic valve diameter (AV), systemic vascular resistance (SVR), and stroke volume variation (SVV); (Cronbach’s alpha 0.76–0.98). Percentages of error in all parameters were acceptable by Bland-Altman analysis (9.2–28.8%) except SVR (30.8%) and SVV (257.1%). Conclusion Three noninvasive methods might be used interchangeably in pediatric critical care settings with stable hemodynamics. Interpretation of SVV and SVR measurements must be done with prudence.en_US
dc.identifier.citationPLoS ONE. Vol.13, No.6 (2018)en_US
dc.identifier.doi10.1371/journal.pone.0199203en_US
dc.identifier.issn19326203en_US
dc.identifier.other2-s2.0-85048752066en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/44742
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85048752066&origin=inwarden_US
dc.subjectAgricultural and Biological Sciencesen_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.titleComparison of three non-invasive hemodynamic monitoring methods in critically ill childrenen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85048752066&origin=inward

Files

Collections