Publication: Simultaneous COD removal and PHA production in an activated sludge system under different temperatures
dc.contributor.author | Sopa Chinwetkitvanich | en_US |
dc.contributor.author | Clifford W. Randall | en_US |
dc.contributor.author | Thongchai Panswad | en_US |
dc.contributor.other | Chulalongkorn University | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.contributor.other | Virginia Polytechnic Institute and State University | en_US |
dc.date.accessioned | 2018-09-13T06:36:08Z | |
dc.date.available | 2018-09-13T06:36:08Z | |
dc.date.issued | 2009-12-01 | en_US |
dc.description.abstract | The purpose of this study was to investigate PHA production by activated sludge biomass under different temperatures. The two-step approach, i.e. utilizing a growth phase followed by a nutrient(s) limitation phase, was applied to stimulate PHA accumulation. Each of three intended temperatures, 10°C, 20°C and 30°C, was investigated with combined N&P limitation. Four liter (L) fully aerobic SBRs were used for all experiments, and operated with a 6 h cycle time, a 10 h HRT and a 10 day SRT. The maximum PHA cellular contents and total concentrations achieved during the N&P limitation periods in the 10 and 20°C systems were very similar, i.e. 45 and 43 % of the TSS and 2133 and 2239 mg/l, respectively, whereas the 30°C results were lower at 33 % of TSS and 1476 mg/l. The biomass temperature clearly had a strong inverse effect upon PHA productivity. It decreased from 427 and 204 to 148 mg/l-day as reactor temperature increased from 10 to 20 and 30°C, respectively. As well, the PHA yields decreased from 0.38 to 0.16 and 0.11 mg PHA/mg CODu, respectively. The results strongly indicate that activated sludge PHA accumulation stimulated by combined N and P limitation is inversely correlated with temperature. | en_US |
dc.identifier.citation | Engineering Journal. Vol.13, No.3 (2009), 1-12 | en_US |
dc.identifier.doi | 10.4186/ej.2009.13.3.1 | en_US |
dc.identifier.issn | 01258281 | en_US |
dc.identifier.other | 2-s2.0-79960831527 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/27543 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79960831527&origin=inward | en_US |
dc.subject | Engineering | en_US |
dc.title | Simultaneous COD removal and PHA production in an activated sludge system under different temperatures | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79960831527&origin=inward | en_US |