Publication:
Screening may not be accurate word to represent the cases submitted to PET/CT evaluation for primary tumor in a patient who has abnormal serum tumor marker

dc.contributor.authorSunanta Chiewviten_US
dc.contributor.authorSaiphet Phasuken_US
dc.contributor.authorSavitree Surapakoen_US
dc.contributor.authorWantana Juiklomen_US
dc.contributor.authorPipat Chiewviten_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherChulabhorn Cancer Centeren_US
dc.date.accessioned2018-09-24T09:32:24Z
dc.date.available2018-09-24T09:32:24Z
dc.date.issued2010-03-01en_US
dc.description.abstractObjective: Determine the value of PET/CT in unknown primary cancer patient with high tumor marker and negative study for clinical and conventional imaging. Material and Method: A retrospective database review of 417 patients who received PET/CT between July 2006 and August 2007 in National cyclotron and PET center at Chulabhorn cancer center was done. Patients were included in this study if the diagnosis were unknown primary cancer and rising tumor marker. Twelve patients were included in this study. Data included age, gender, tumor marker rising, anatomical imaging finding (CT and MRI), PET finding and clinical follow-up. Results: Nine cases had normal PET/CT. This showed that PET/CT does not get more information than conventional imaging. The PET scan showed positive in three cases, #5, #6 and #10. Two cases were false positive, #5 and #6. Case #5 had clinical follow-up for one year and revealed to be normal. Case #6 PET showed markedly glucose avid lesion at tumor thrombus but contrast CT confirm blood clot and the patient was treat with wafarin and claxane. The follow-up clinical showed improvement. The high serum CA 125 explained by lung infarction caused the false positive. In case#10, the PET/CT suggested lung cancer at basal segment of LLL. Conclusion: Screening 18F FDG PET/CT is not appropriate in unknown primary with rising tumor marker and normal conventional imaging is required.en_US
dc.identifier.citationJournal of the Medical Association of Thailand. Vol.93, No.3 (2010), 330-336en_US
dc.identifier.issn01252208en_US
dc.identifier.issn01252208en_US
dc.identifier.other2-s2.0-77951902357en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/29750
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77951902357&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleScreening may not be accurate word to represent the cases submitted to PET/CT evaluation for primary tumor in a patient who has abnormal serum tumor markeren_US
dc.typeReviewen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77951902357&origin=inwarden_US

Files

Collections