Publication:
Correlation between pixel values in a cone-beam computed tomographic scanner and the computed tomographic values in a multidetector row computed tomographic scanner

dc.contributor.authorJira Chindasombatjaroenen_US
dc.contributor.authorNaoya Kakimotoen_US
dc.contributor.authorHiroaki Shimamotoen_US
dc.contributor.authorShumei Murakamien_US
dc.contributor.authorSouhei Furukawaen_US
dc.contributor.otherOsaka Universityen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-05-03T08:26:32Z
dc.date.available2018-05-03T08:26:32Z
dc.date.issued2011-09-01en_US
dc.description.abstractObjectives: The study's objectives were to investigate the correlation between pixel values obtained from a cone-beam computed tomographic (CBCT) scanner and the computed tomographic (CT) values from a multidetector row CT scanner and to determine whether they have a linear relationship at various tube voltages and tube currents. Methods: A phantom with different concentrations of contrast medium at the center of a multidetector row CT and a CBCT scanner was scanned at various imaging parameters. Computed tomographic values and pixel values were measured using ImageJ. Regression analysis was performed, as well as correlation tests with a Pearson correlation coefficient. Results: A significant correlation between pixel values and the CT values of the same specimen was observed (P < 0.0001), and a linear relationship was found between the values from the 2 scanners at each parameter. Conclusions: A high correlation and linear relationship between the CT values and pixel values were found at each parameter. Therefore, linear functions can be used to convert a pixel value from the CBCT machine used in this study to the CT values. Copyright © 2011 by Lippincott Williams & Wilkins.en_US
dc.identifier.citationJournal of Computer Assisted Tomography. Vol.35, No.5 (2011), 662-665en_US
dc.identifier.doi10.1097/RCT.0b013e31822d9725en_US
dc.identifier.issn15323145en_US
dc.identifier.issn03638715en_US
dc.identifier.other2-s2.0-80053008019en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/12339
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=80053008019&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleCorrelation between pixel values in a cone-beam computed tomographic scanner and the computed tomographic values in a multidetector row computed tomographic scanneren_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=80053008019&origin=inwarden_US

Files

Collections