Publication: Correlation between pixel values in a cone-beam computed tomographic scanner and the computed tomographic values in a multidetector row computed tomographic scanner
dc.contributor.author | Jira Chindasombatjaroen | en_US |
dc.contributor.author | Naoya Kakimoto | en_US |
dc.contributor.author | Hiroaki Shimamoto | en_US |
dc.contributor.author | Shumei Murakami | en_US |
dc.contributor.author | Souhei Furukawa | en_US |
dc.contributor.other | Osaka University | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.date.accessioned | 2018-05-03T08:26:32Z | |
dc.date.available | 2018-05-03T08:26:32Z | |
dc.date.issued | 2011-09-01 | en_US |
dc.description.abstract | Objectives: The study's objectives were to investigate the correlation between pixel values obtained from a cone-beam computed tomographic (CBCT) scanner and the computed tomographic (CT) values from a multidetector row CT scanner and to determine whether they have a linear relationship at various tube voltages and tube currents. Methods: A phantom with different concentrations of contrast medium at the center of a multidetector row CT and a CBCT scanner was scanned at various imaging parameters. Computed tomographic values and pixel values were measured using ImageJ. Regression analysis was performed, as well as correlation tests with a Pearson correlation coefficient. Results: A significant correlation between pixel values and the CT values of the same specimen was observed (P < 0.0001), and a linear relationship was found between the values from the 2 scanners at each parameter. Conclusions: A high correlation and linear relationship between the CT values and pixel values were found at each parameter. Therefore, linear functions can be used to convert a pixel value from the CBCT machine used in this study to the CT values. Copyright © 2011 by Lippincott Williams & Wilkins. | en_US |
dc.identifier.citation | Journal of Computer Assisted Tomography. Vol.35, No.5 (2011), 662-665 | en_US |
dc.identifier.doi | 10.1097/RCT.0b013e31822d9725 | en_US |
dc.identifier.issn | 15323145 | en_US |
dc.identifier.issn | 03638715 | en_US |
dc.identifier.other | 2-s2.0-80053008019 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/12339 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=80053008019&origin=inward | en_US |
dc.subject | Medicine | en_US |
dc.title | Correlation between pixel values in a cone-beam computed tomographic scanner and the computed tomographic values in a multidetector row computed tomographic scanner | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=80053008019&origin=inward | en_US |