Publication: Improving microbial air quality in air-conditioned mass transport buses by opening the bus exhaust ventilation fans
Issued Date
2005-07-01
Resource Type
ISSN
01251562
Other identifier(s)
2-s2.0-27744447988
Rights
Mahidol University
Rights Holder(s)
SCOPUS
Bibliographic Citation
Southeast Asian Journal of Tropical Medicine and Public Health. Vol.36, No.4 (2005), 1032-1038
Suggested Citation
Pipat Luksamijarulkul, Nongphon Arunchai, Soavalug Luksamijarulkul, Orawan Kaewboonchoo Improving microbial air quality in air-conditioned mass transport buses by opening the bus exhaust ventilation fans. Southeast Asian Journal of Tropical Medicine and Public Health. Vol.36, No.4 (2005), 1032-1038. Retrieved from: https://repository.li.mahidol.ac.th/handle/20.500.14594/16914
Research Projects
Organizational Units
Authors
Journal Issue
Thesis
Title
Improving microbial air quality in air-conditioned mass transport buses by opening the bus exhaust ventilation fans
Other Contributor(s)
Abstract
The air quality in air-conditioned mass transport buses may affect bus drivers' health. In-bus air quality improvement with the voluntary participation of bus drivers by opening the exhaust ventilation fans in the bus was implemented in the Seventh Bus Zone of Bangkok Mass Transit Authority. Four bus numbers, including bus numbers 16, 63, 67 and 166, were randomly selected to investigate microbial air quality and to observe the effect of opening the exhaust ventilation fans in the bus. With each bus number, 9 to 10 air-conditioned buses (total, 39 air-conditioned buses) were included. In-bus air samples were collected at 5 points in each studied bus using the Millipore Air Tester. A total of 195 air samples were cultured for bacterial and fungal counts. The results reveal that the exhaust ventilation fans of 17 air-conditioned buses (43.6%) were opened to ventilate inbus air during the cycle of the bus route. The means ± SD of bacterial counts and fungal counts in the studied buses with opened exhaust ventilation fans (83.8 ± 70.7 and 38.0 ± 42.8 cfu/m3) were significantly lower than those in the studied buses without opened exhaust ventilation fans (199.6 ± 138.8 and 294.1 ± 178.7 cfu/m3), p<0.0005. All the air samples collected from the studied buses with opened exhaust ventilation fans were at acceptable levels (<500 cfu/m3) compared with 4.6% of the air samples collected from the studied buses without opened exhaust ventilation fans, which had high levels (>500 cfu/m3). Of the studied buses with opened exhaust ventilation fans (17 buses), the bacterial and fungal counts after opening the exhaust ventilation fans (68.3 ± 33.8 and 28.3 ± 19.3 cfu/m3) were significantly lower than those before opening the exhaust ventilation fans (158.3 ± 116.9 and 85.3 ± 71.2 cfu/m3), p<0.005.