dc.description.abstract | © 2019, © 2019 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group. The purposes of this study were to develop and evaluate the test-retest reliability of a specific low-cost three-dimensional webcam recording system (3D-WCRS) and compare its reliability to a standard motion analysis system. Twenty healthy volunteers comprised of 5 males and 15 females with a mean age of 22.90 years and mean BMI of 22.72 kg/m2 were investigated for angles of hip, knee and ankle joints in three planes while walking at a self-selected speed. Intraclass correlation coefficients (ICCs) were used to evaluate as well as compare the test-retest reliability of the 3D-WCRS and standard motion analysis system. Standard error of measurement (SEM) was also analyzed for the purposes of the study. The results exhibited excellent test-retest reliability for the 3D-WCRS (ICCs ranged between 0.93 and 0.99, p = 0.001) in the three joints and planes. The standard motion analysis system demonstrated excellent reliability for all joints and planes (ICCs ranged between 0.99 and 1.00, p = 0.001). Minimal SEM values were observed in both the 3D-WCRS and standard motion analysis systems. Therefore, the developed low-cost 3D-WCRS exhibits good to excellent test-retest reliability. The test-retest reliability of the 3D-WCRS is likely to be comparable to a standard motion analysis system. | en_US |
dc.identifier.citation | International Biomechanics. Vol.6, No.1 (2019), 85-92 | en_US |
dc.identifier.doi | 10.1080/23335432.2019.1671221 | en_US |
dc.identifier.issn | 23335432 | en_US |
dc.identifier.other | 2-s2.0-85073204893 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/50685 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85073204893&origin=inward | en_US |
dc.subject | Computer Science | en_US |
dc.subject | Engineering | en_US |
dc.subject | Health Professions | en_US |
dc.subject | Medicine | en_US |
dc.title | Reliability of a low-cost webcam recording system for three-dimensional lower limb gait analysis | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85073204893&origin=inward | en_US |