Publication: Electrocatalytic detection of insulin at RuOx/carbon nanotube-modified carbon electrodes
dc.contributor.author | Joseph Wang | en_US |
dc.contributor.author | Tanin Tangkuaram | en_US |
dc.contributor.author | Suchera Loyprasert | en_US |
dc.contributor.author | Terannie Vazquez-Alvarez | en_US |
dc.contributor.author | Waret Veerasai | en_US |
dc.contributor.author | Proespichaya Kanatharana | en_US |
dc.contributor.author | Panote Thavarungkul | en_US |
dc.contributor.other | Arizona State University | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.contributor.other | Prince of Songkla University | en_US |
dc.date.accessioned | 2018-08-24T01:43:50Z | |
dc.date.available | 2018-08-24T01:43:50Z | |
dc.date.issued | 2007-01-02 | en_US |
dc.description.abstract | A bilayer surface coating, prepared by electrodepositing ruthenium oxide (RuOx) onto a carbon nanotube (CNT) layer, offers dramatic improvements in the stability and sensitivity of voltammetric and amperometric measurements of insulin compared to the individual (CNT or RuOx) coated electrodes. The enhanced electrocatalytic activity towards insulin is indicated from lowering the potential of the oxidation process (starting around 0.35 versus Ag/AgCl) and the substantially higher sensitivity over the entire potential range. A wide linear dynamic range (10-800 nM) was achieved with a detection limit of 1 nM. The marked electrocatalytic activity of the RuOx/CNT coating towards insulin is coupled with a greatly enhanced stability. For example, the insulin amperometric response of the RuOx/CNT-coated electrodes is highly stable, with 97% of the initial activity remaining after 60 min stirring of 2 × 10-6M solution (compared to significantly faster current diminutions at the RuOx- or CNT-coated surfaces). The results suggest great promise for miniaturized sensors and detectors for monitoring insulin. © 2006 Elsevier B.V. All rights reserved. | en_US |
dc.identifier.citation | Analytica Chimica Acta. Vol.581, No.1 (2007), 1-6 | en_US |
dc.identifier.doi | 10.1016/j.aca.2006.07.084 | en_US |
dc.identifier.issn | 00032670 | en_US |
dc.identifier.other | 2-s2.0-33751194854 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/24269 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33751194854&origin=inward | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.subject | Chemistry | en_US |
dc.subject | Environmental Science | en_US |
dc.title | Electrocatalytic detection of insulin at RuOx/carbon nanotube-modified carbon electrodes | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33751194854&origin=inward | en_US |