Publication:
Simple flow injection for determination of sulfite by amperometric detection using glassy carbon electrode modified with carbon nanotubes-PDDA-gold nanoparticles

dc.contributor.authorMaliwan Amatatongchaien_US
dc.contributor.authorWongduan Sroyseeen_US
dc.contributor.authorSanoe Chairamen_US
dc.contributor.authorDuangjai Nacaprichaen_US
dc.contributor.otherUbon Rajathanee Universityen_US
dc.contributor.otherFlow Innovation-Research for Science and Technology Laboratories (FIRST Labs.)en_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-11-23T09:59:35Z
dc.date.available2018-11-23T09:59:35Z
dc.date.issued2015-01-01en_US
dc.description.abstract© 2014 Elsevier B.V. All rights reserved. A new approach is presented for sensitive and selective measurement of sulfite (SO32-) in beverages based on a simple flow injection system with amperometric detection. In this work, the sulfite sensor was a glassy carbon electrode modified with multiwall carbon nanotubes-poly(diallyldimethylammonium chloride)-gold nanoparticles composites (CNTs-PDDA-AuNPs/GC). Electrochemical oxidation of sulfite with this electrode was first studied in 0.1 M phosphate buffer (pH 7.0) using cyclic voltammetry. The results indicated that the CNTs-PDDA-AuNPs/GC electrode possesses electrocatalytic activity for the oxidation of sulfite with high sensitivity and selectivity. Sulfite was quantified using amperometric measurement with the new sensor at +0.4 V vs Ag/AgCl in conjunction with flow injection. The linear working range for the quantitation of sulfite was 2-200 mg L-1(r2=0.998) with a detection limit of 0.03 mg L-1(3σ of blank) and an estimated precision of 1.5%.The proposed method was successfully applied to the determination of sulfite in fruit juices and wines with a sample throughput of 23 samples per hour.en_US
dc.identifier.citationTalanta. Vol.133, (2015), 134-141en_US
dc.identifier.doi10.1016/j.talanta.2014.07.055en_US
dc.identifier.issn00399140en_US
dc.identifier.other2-s2.0-84913589078en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/35782
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84913589078&origin=inwarden_US
dc.subjectChemistryen_US
dc.titleSimple flow injection for determination of sulfite by amperometric detection using glassy carbon electrode modified with carbon nanotubes-PDDA-gold nanoparticlesen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84913589078&origin=inwarden_US

Files

Collections