Publication: Simple flow injection for determination of sulfite by amperometric detection using glassy carbon electrode modified with carbon nanotubes-PDDA-gold nanoparticles
dc.contributor.author | Maliwan Amatatongchai | en_US |
dc.contributor.author | Wongduan Sroysee | en_US |
dc.contributor.author | Sanoe Chairam | en_US |
dc.contributor.author | Duangjai Nacapricha | en_US |
dc.contributor.other | Ubon Rajathanee University | en_US |
dc.contributor.other | Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs.) | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.date.accessioned | 2018-11-23T09:59:35Z | |
dc.date.available | 2018-11-23T09:59:35Z | |
dc.date.issued | 2015-01-01 | en_US |
dc.description.abstract | © 2014 Elsevier B.V. All rights reserved. A new approach is presented for sensitive and selective measurement of sulfite (SO32-) in beverages based on a simple flow injection system with amperometric detection. In this work, the sulfite sensor was a glassy carbon electrode modified with multiwall carbon nanotubes-poly(diallyldimethylammonium chloride)-gold nanoparticles composites (CNTs-PDDA-AuNPs/GC). Electrochemical oxidation of sulfite with this electrode was first studied in 0.1 M phosphate buffer (pH 7.0) using cyclic voltammetry. The results indicated that the CNTs-PDDA-AuNPs/GC electrode possesses electrocatalytic activity for the oxidation of sulfite with high sensitivity and selectivity. Sulfite was quantified using amperometric measurement with the new sensor at +0.4 V vs Ag/AgCl in conjunction with flow injection. The linear working range for the quantitation of sulfite was 2-200 mg L-1(r2=0.998) with a detection limit of 0.03 mg L-1(3σ of blank) and an estimated precision of 1.5%.The proposed method was successfully applied to the determination of sulfite in fruit juices and wines with a sample throughput of 23 samples per hour. | en_US |
dc.identifier.citation | Talanta. Vol.133, (2015), 134-141 | en_US |
dc.identifier.doi | 10.1016/j.talanta.2014.07.055 | en_US |
dc.identifier.issn | 00399140 | en_US |
dc.identifier.other | 2-s2.0-84913589078 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/35782 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84913589078&origin=inward | en_US |
dc.subject | Chemistry | en_US |
dc.title | Simple flow injection for determination of sulfite by amperometric detection using glassy carbon electrode modified with carbon nanotubes-PDDA-gold nanoparticles | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84913589078&origin=inward | en_US |