Publication: Development and comparison of the real-time amplification based methods - NASBA-Beacon, RT-PCR TaqMan and RT-PCR hybridization probe assays - For the qualitative detection of sars coronavirus
| dc.contributor.author | Wasun Chantratita | en_US |
| dc.contributor.author | Wiroj Pongtanapisit | en_US |
| dc.contributor.author | Wantanich Piroj | en_US |
| dc.contributor.author | Chutatip Srichunrasmi | en_US |
| dc.contributor.author | Somying Seesuai | en_US |
| dc.contributor.other | Mahidol University | en_US |
| dc.date.accessioned | 2018-07-24T03:48:46Z | |
| dc.date.available | 2018-07-24T03:48:46Z | |
| dc.date.issued | 2004-09-01 | en_US |
| dc.description.abstract | The aim of this study was to develop a rapid, sensitive and robust procedure for the qualitative detection of SARS coronavirus RNA. Three unique detection formats were developed for real-time RNA amplification assays: a post amplification detection step with a virus-specific internal capture probe based on Taqman (RT-PCR TaqMan assay), hybridization probe (RT-PCR hybridization probe assay) and a real-time assay with virus-specific molecular beacon probes (NASBA-Beacon assay). The analytical sensitivity or reproducibility of the test results among those three assays was compared. All assays yielded results by detecting SARS coronavirus targeting the BNI-1 region in less than 2 hours. RNA detection by all the formats was unaffected by the presence of human sputum. The limits of detection were at least 10 copies of input RNA for both RT-PCR formats (RT-PCR TaqMan and RT-PCR hybridization probe assays), while the NASBA-Beacon assay could detect as little as 1 copy per reaction, with high reproducibility of the coefficient of variation (CV) of <10. These results demonstrate that real-time NASBA provides a rapid and sensitive alternative to RT-PCR for the routine qualitative assay of sputum for SARS corona viral RNA detection. | en_US |
| dc.identifier.citation | Southeast Asian Journal of Tropical Medicine and Public Health. Vol.35, No.3 (2004), 623-629 | en_US |
| dc.identifier.issn | 01251562 | en_US |
| dc.identifier.other | 2-s2.0-8444228607 | en_US |
| dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/123456789/21553 | |
| dc.rights | Mahidol University | en_US |
| dc.rights.holder | SCOPUS | en_US |
| dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=8444228607&origin=inward | en_US |
| dc.subject | Medicine | en_US |
| dc.title | Development and comparison of the real-time amplification based methods - NASBA-Beacon, RT-PCR TaqMan and RT-PCR hybridization probe assays - For the qualitative detection of sars coronavirus | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication | |
| mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=8444228607&origin=inward | en_US |