Publication:
Microfluidic paper-based analytical device for quantification of lead using reaction band-length for identification of bullet hole and its potential for estimating firing distance

dc.contributor.authorSupatana Bukingen_US
dc.contributor.authorPhoonthawee Saetearen_US
dc.contributor.authorWarawut Tiyapongpattanaen_US
dc.contributor.authorKanchana Uraisinen_US
dc.contributor.authorPrapin Wilairaten_US
dc.contributor.authorDuangjai Nacaprichaen_US
dc.contributor.authorNuanlaor Ratanawimarnwongen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherThammasat Universityen_US
dc.contributor.otherSrinakharinwirot Universityen_US
dc.contributor.otherFlow Innovation-Research for Science and Technology Laboratories (FIRST Labs.en_US
dc.date.accessioned2019-08-23T10:52:35Z
dc.date.available2019-08-23T10:52:35Z
dc.date.issued2018-01-01en_US
dc.description.abstract© The Japan Society for Analytical Chemistry, 2018. A low-cost and user-friendly microfluidic paper-based analytical device (μPAD) was developed for identification of bullet hole from gunshot residue (GSR) on cotton fabric target. The device (25 × 82 mm) is made of filter paper with a printed pattern consisting of a circular sample loading reservoir (6 mm i.d.), a circular waste reservoir (4 mm i.d.) and a straight flow channel (3 mm wide and 60 mm long). A sticker with a ruler scale in millimeters was mounted alongside the channel. The straight channel is first impregnated with rhodizonate and dried at ambient temperature. Tartrate extract of the target fabric is loaded on the sample reservoir. If Pb(II) ions are present in the extract, pink streak of Pb(II)- rhodizonate precipitate is formed as the sample solution flows from the reservoir along the channel. The length of the pink strip is employed to estimate the firing distance.en_US
dc.identifier.citationAnalytical Sciences. Vol.34, No.1 (2018), 83-89en_US
dc.identifier.doi10.2116/analsci.34.83en_US
dc.identifier.issn13482246en_US
dc.identifier.issn09106340en_US
dc.identifier.other2-s2.0-85041840212en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/45524
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85041840212&origin=inwarden_US
dc.subjectChemistryen_US
dc.titleMicrofluidic paper-based analytical device for quantification of lead using reaction band-length for identification of bullet hole and its potential for estimating firing distanceen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85041840212&origin=inwarden_US

Files

Collections