Publication:
Stress analysis of two craniofacial implants in implant retained auricular prostheses

dc.contributor.authorAhmed Abdulrahman Abbasen_US
dc.contributor.authorTeeranoot Chanthasopeephanen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherKing Mongkuts University of Technology Thonburien_US
dc.date.accessioned2018-11-23T10:00:46Z
dc.date.available2018-11-23T10:00:46Z
dc.date.issued2015-11-04en_US
dc.description.abstract© 2015 IEEE. Implant-retained auricular prostheses require attachments to connect the implants and prostheses. Different attachments have different retention forces and hence different stress is transmitted to the implants. Splinting the implants together with a Hader bar allows the combination of different attachments with the Hader bar and allows changes in the amount and pattern of stress on the implants. However, the amount of removal force is also influenced by the retention components and the direction of removal of the prosthesis. In this paper, we studied the stress distribution around two craniofacial implants, in an auricular prosthesis, according to the removal forces, among three different attachment combinations and evaluated the stress distribution around two craniofacial implants in an auricular prosthesis with removal force at normal direction. The mean removal force was experimentally determined and the models were created using finite element software to analyze the distribution of von-Mises stress. Within the limitations of this study, the prosthodontist should place an emphasis on encouraging patients to remove the prosthesis at 90 degrees and if possible use a low retentive attachment to reduce the stress.en_US
dc.identifier.citationProceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. Vol.2015-November, (2015), 4816-4819en_US
dc.identifier.doi10.1109/EMBC.2015.7319471en_US
dc.identifier.issn1557170Xen_US
dc.identifier.other2-s2.0-84953336058en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/35797
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84953336058&origin=inwarden_US
dc.subjectComputer Scienceen_US
dc.subjectEngineeringen_US
dc.subjectMedicineen_US
dc.titleStress analysis of two craniofacial implants in implant retained auricular prosthesesen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84953336058&origin=inwarden_US

Files