Publication:
Dynamic thermal properties estimation using sensitivity coefficients for rapid heating process

dc.contributor.authorAnbuhkani Muniandyen_US
dc.contributor.authorPatnarin Benyathiaren_US
dc.contributor.authorDharmendra K. Mishraen_US
dc.contributor.authorFerhan Ozadalien_US
dc.contributor.otherReckitt Benckiser Group plcen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherPurdue Universityen_US
dc.date.accessioned2022-08-04T07:55:53Z
dc.date.available2022-08-04T07:55:53Z
dc.date.issued2021-08-01en_US
dc.description.abstractThermal conductivity determination of food at temperatures >100◦C still remains a challenge. The objective of this study was to determine the temperature-dependent thermal conductivity of food using rapid heating (TPCell). The experiments were designed based on scaled sensitivity coefficient (SSC), and the estimated thermal conductivity of potato puree was compared between the constant temperature heating at 121.10◦C (R12B10T1) and the rapid heating (R22B10T1). Temperature-dependent thermal conductivity models along with a constant conductivity were used for estimation. R22B10T1 experiment using the k model provided reliable measurements as compared to R12B10T1 with thermal conductivity values from 0.463 ± 0.011 W m−1 K−1 to 0.450 ± 0.016 W m−1 K−1 for 25–140◦C and root mean squares error (RMSE) of 1.441. In the R12B10T1 experiment, the analysis showed the correlation of residuals, which made the estimation less reliable. The thermal conductivity values were in the range of 0.444 ± 0.012 W m−1 K−1 to 0.510 ± 0.034 W m−1 K−1 for 20–120◦C estimated using the k model. Temperature-dependent models (linear and k models) provided a better estimate than the single parameter thermal conductivity determination with low RMSE for both types of experiments. SSC can provide insight in designing dynamic experiments for the determination of thermal conductivity coefficient.en_US
dc.identifier.citationFoods. Vol.10, No.8 (2021)en_US
dc.identifier.doi10.3390/foods10081954en_US
dc.identifier.issn23048158en_US
dc.identifier.other2-s2.0-85113440483en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/75605
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85113440483&origin=inwarden_US
dc.subjectAgricultural and Biological Sciencesen_US
dc.subjectHealth Professionsen_US
dc.subjectImmunology and Microbiologyen_US
dc.subjectSocial Sciencesen_US
dc.titleDynamic thermal properties estimation using sensitivity coefficients for rapid heating processen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85113440483&origin=inwarden_US

Files

Collections