Publication:
Effects of C-factor and resin volume on the bonding to root canal with and without fibre post insertion

dc.contributor.authorJuthatip Aksornmuangen_US
dc.contributor.authorMasatoshi Nakajimaen_US
dc.contributor.authorPisol Senawongseen_US
dc.contributor.authorJunji Tagamien_US
dc.contributor.otherPrince of Songkla Universityen_US
dc.contributor.otherTokyo Medical and Dental Universityen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-05-03T08:09:55Z
dc.date.available2018-05-03T08:09:55Z
dc.date.issued2011-06-01en_US
dc.description.abstractObjectives: The aim of this study was to evaluate the effects of C-factor and resin volume on the regional bond strength of dual-cure luting resin to root canal dentine. Methods: Twelve single-root human premolars were decoronated and post space prepared to a depth of 8 mm, with a diameter of 1.5 mm for six roots and 1.75 mm for the other six. Root canal dentine was treated with a dual-cure bonding system and light-cured for 20 s. Specimens were filled with a dual-cure resin composite with or without insertion of 1.4-mm-diameter light-transmitting glass fibre posts, followed by light-curing for 60 s from the coronal direction. After 24 h water storage, each specimen was serially sliced into eight 0.6 mm × 0.6 mm thick beams for a microtensile bond strength test. Failure modes were observed using SEM. Bond strength data were divided into coronal and apical regions and statistically analysed. Results: For both sizes of post space, bond strengths dramatically decreased when fibre posts were inserted. There were no significant differences in microtensile bond strength between 1.5 mm and 1.75 mm canal width, regardless of fibre post insertion. Regional differences in bond strength were found only in the resin-filled canals. Conclusions:: The increase of C-factor of the root canal system by insertion of a fibre post had a detrimental effect on the bond strength to root canal dentine. On the other hand, the change of resin volume had no significant effect on bonding. © 2011 Elsevier Ltd. All rights reserved.en_US
dc.identifier.citationJournal of Dentistry. Vol.39, No.6 (2011), 422-429en_US
dc.identifier.doi10.1016/j.jdent.2011.03.007en_US
dc.identifier.issn03005712en_US
dc.identifier.other2-s2.0-79958008437en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/11829
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79958008437&origin=inwarden_US
dc.subjectDentistryen_US
dc.titleEffects of C-factor and resin volume on the bonding to root canal with and without fibre post insertionen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79958008437&origin=inwarden_US

Files