Publication:
Evaluation of Thrombi-Stat MC1 for whole blood and plasma international normalized ratio in comparison with a laboratory method

dc.contributor.authorC. Tantanateen_US
dc.contributor.authorP. Tientadakulen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-10-19T04:41:54Z
dc.date.available2018-10-19T04:41:54Z
dc.date.issued2013-02-01en_US
dc.description.abstractIntroduction: The precision and comparability of the international normalized ratio (INR) analyzed by the Thrombi-Stat MC1 coagulation testing system were evaluated before using as a point-of-care testing. Methods: Three levels of control materials were used for within-run and between-run precision study. Comparison study of INR determination from citrated whole blood (INR-WB) and citrated plasma (INR-PL) analyzed by the Thrombi-Stat MC1 with those by the validated method, Sysmex®CS-2100i (INR-CS), was performed. Results: The within-run coefficient of variations (CVs) of INR by the Thrombi-Stat MC1 were 3.60% to 4.80%. For between-run precision, the CVs were 4.26 to 4.93%. Fifty-four plasmas from patients receiving warfarin were included for comparability testing. There were good correlation and agreement between both INR-WB and INR-PL compared with INR-CS. Eighty-seven percent of INR-WB and 100% of INR-PL were within ± 0.5 units of the INR-CS. Given that the therapeutic range was INR-CS of 2-3, 3.7% of INR-WB and 5.56% of INR-PL were discordant with the INR-CS. Conclusion: The precision and comparability to validated method of the Thrombi-Stat MC1 were acceptable. Either citrated whole blood or plasma may be used as samples in this system. Impact on the management of patients must be taken into consideration prior to the implementation of this system. © 2012 Blackwell Publishing Ltd.en_US
dc.identifier.citationInternational Journal of Laboratory Hematology. Vol.35, No.1 (2013), 55-60en_US
dc.identifier.doi10.1111/j.1751-553X.2012.01461.xen_US
dc.identifier.issn1751553Xen_US
dc.identifier.issn17515521en_US
dc.identifier.other2-s2.0-84872265112en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/31367
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84872265112&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectMedicineen_US
dc.titleEvaluation of Thrombi-Stat MC1 for whole blood and plasma international normalized ratio in comparison with a laboratory methoden_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84872265112&origin=inwarden_US

Files

Collections