Analysis of backflow within an external centrifugal blood pump for ventricular assist device

dc.contributor.authorChitsanupong Rungsirigulnanen_US
dc.contributor.authorRavi Laohasurayodhinen_US
dc.contributor.authorThisana Tuanthammaruken_US
dc.contributor.authorYanee Chusrien_US
dc.contributor.authorPaweena Diloksumpanen_US
dc.contributor.authorPhornphop Naiyanetren_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-10-19T04:54:28Z
dc.date.available2018-10-19T04:54:28Z
dc.date.issued2013-12-01en_US
dc.description.abstractDuring left ventricular support by rotary blood pumps (RBPs), pump speed plays an important role in the amount of heart support. The reducing of pump speed seems important in order to prevent some adverse events in the heart valve. However, when pump speed was reduced, the backflow which is the flow that has the reverse direction to blood pumping direction may occur more easily. This is due to the amount of pressure at an outlet of pump. Head pressure and pump flow curve (HQ-curve) is the graph that shows the performance of speed, head pressure and flow rate in the blood pump. In this study, two impellers from MUAD-VAD02 were used; 90-degree-angle straight blade (90SB) and 130 degrees straight blade (130BSB). The backflow of two impellers were investigated at three pump speeds (1000, 1400 and 1800 rpm) using HQ-curve, negative flow rate vs. time, and pressure vs. time. The experimental study uses in vitro testing by simulating the natural circulatory system with RBPs in the mock circulation loop system. The back flow of 90SB had more negative flow than BSB at all three speeds. In conclusion, BSB- impeller was chosen over the 90SB-impeller because at the same head pressure and speed in HQ-curve, the BSB impeller has less negative flow. © 2013 IEEE.en_US
dc.identifier.citationBMEiCON 2013 - 6th Biomedical Engineering International Conference. (2013)en_US
dc.identifier.doi10.1109/BMEiCon.2013.6687729en_US
dc.identifier.other2-s2.0-84893232908en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/31715
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84893232908&origin=inwarden_US
dc.subjectEngineeringen_US
dc.titleAnalysis of backflow within an external centrifugal blood pump for ventricular assist deviceen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84893232908&origin=inwarden_US

Files

Collections