Publication:
Influence of an object's z-axis location and location on the axial plane on the voxel value representation and uniformity in cone beam computed tomography

dc.contributor.authorKanako Nishinoen_US
dc.contributor.authorHiroaki Shimamotoen_US
dc.contributor.authorNaoya Kakimotoen_US
dc.contributor.authorTomomi Tsujimotoen_US
dc.contributor.authorJira Chindasombatjaroenen_US
dc.contributor.authorShumei Murakamien_US
dc.contributor.authorSouhei Furukawaen_US
dc.contributor.otherOsaka Universityen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-11-09T02:12:27Z
dc.date.available2018-11-09T02:12:27Z
dc.date.issued2014-01-01en_US
dc.description.abstract© 2014 Elsevier Inc. Objective This study aimed to determine the influence of an object's z-axis location and location on the axial plane on the voxel values in cone beam computed tomography.Study Design The CTP401 and CTP486 of the Catphan 500 phantom were scanned with an Alphard-3030 at 6 locations in the z-axis.Results In CTP401, the voxel values of 3 inserts showed the lowest values when the center of the radiation field corresponded to under 2 or 4 cm of the z-axis center of CTP401. In CTP486, the voxel values showed the lowest values when the center of the radiation field corresponded to under 2 or 4 cm of the z-axis center of CTP486. On the same axial plane, the voxel values at the center showed significantly lower values than the off-center locations (P =.002).Conclusions The voxel values in the Alphard-3030 changed based on the z-axis location of the radiation field and were nonuniform on the same axial plane.en_US
dc.identifier.citationOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology. Vol.118, No.5 (2014), 619-624en_US
dc.identifier.doi10.1016/j.oooo.2014.08.010en_US
dc.identifier.issn22124403en_US
dc.identifier.other2-s2.0-84908211114en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/33785
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84908211114&origin=inwarden_US
dc.subjectDentistryen_US
dc.subjectMedicineen_US
dc.titleInfluence of an object's z-axis location and location on the axial plane on the voxel value representation and uniformity in cone beam computed tomographyen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84908211114&origin=inwarden_US

Files

Collections