Publication: Inter-rater reliability and cross-validation of lumbar stability test
| dc.contributor.author | Peemongkon Wattananon | en_US |
| dc.contributor.author | Chutiporn Thammajaree | en_US |
| dc.contributor.other | Mahidol University | en_US |
| dc.date.accessioned | 2020-01-27T08:49:40Z | |
| dc.date.available | 2020-01-27T08:49:40Z | |
| dc.date.issued | 2019-04-03 | en_US |
| dc.description.abstract | © 2018, © 2018 Informa UK Limited, trading as Taylor & Francis Group. Background: Clinical lumbar stability test can be used to assess individuals’ ability to control their lumbar spine during limb movements. However, inter-rater reliability and validity has not previously been investigated. Therefore, this study aimed to (1) establish inter-rater reliability of lumbar stability test, and (2) cross-validate the lumbar stability test using lab-based equipment as a reference standard. Methods: Twenty-nine healthy university students were recruited. Two fourth year physical therapy students performed lumbar stability test. Lumbar stability levels were used to determine inter-rater reliability using kappa statistics. Then, the participants were asked to perform two trials of 30-s seated balance tests on an unstable chair in eye-open and eye-closed conditions. These trunk neuromuscular control data, including 95% confidence ellipse area (CEA), root-mean-square error along X and Y axes (RMSEx and RMSEy, respectively), were used to cross-validate the lumbar stability test using Spearman’s correlation. Results: Kappa statistics revealed poor to almost perfect agreement (0–1.00). When adjusting for prevalence and bias, inter-rater reliability were fair to almost perfect (0.31–0.59). CEA, RMSEx and RMSEy were greater in eye-closed condition (8.81, 0.30 and 0.48, respectively) comparing with eye-open condition (2.79, 0.16 and 0.26, respectively). Correlation between lumbar stability level and trunk neuromuscular control were fair (r = –0.31–0.34) in eye-open condition and weak (r = –0.14–0.18) in eye-closed condition. Conclusion: Lumbar stability test should be refined to improve inter-rater reliability. Lumbar stability level does not completely represent trunk postural control. Clinicians should use this test with caution. | en_US |
| dc.identifier.citation | European Journal of Physiotherapy. Vol.21, No.2 (2019), 91-97 | en_US |
| dc.identifier.doi | 10.1080/21679169.2018.1494210 | en_US |
| dc.identifier.issn | 21679177 | en_US |
| dc.identifier.issn | 21679169 | en_US |
| dc.identifier.other | 2-s2.0-85053058666 | en_US |
| dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/123456789/50958 | |
| dc.rights | Mahidol University | en_US |
| dc.rights.holder | SCOPUS | en_US |
| dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85053058666&origin=inward | en_US |
| dc.subject | Health Professions | en_US |
| dc.title | Inter-rater reliability and cross-validation of lumbar stability test | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication | |
| mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85053058666&origin=inward | en_US |
