Publication:
Comparison of techniques for minimizing interference of bilirubin on serum creatinine determined by the kinetic Jaffé reaction

dc.contributor.authorPorntip H. Lolekhaen_US
dc.contributor.authorNoppmats Sritongen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-02-27T04:25:34Z
dc.date.available2018-02-27T04:25:34Z
dc.date.issued1994-01-01en_US
dc.description.abstractThis study compared the effect of sodium dodecyl‐sulfate, potassium ferricyanide, and preincubation technique to continuous‐flow analysis and prior deproteinization to correct the negative interference of bilirubin on serum creatinine found by the kinetic Jaffé reaction. Bilirubin increased to 684 μmol/L did not interfere with serum creatinine measured by the methods incorporated with dialysis or deproteinization. Trichloroacetic acid was the best protein precipitant. The reagent incorporated with sodium dodecyl sulfate was more appropriate to minimize bilirubin interference than reagent containing potassium ferricyanide. An increase in potassium ferricyanide concentration resulted in false positive creatinine values. Incorporation of both SDS and potassium ferricyanide in the reagent did not help in minimizing the bilirubin interference over use of each chemical alone. The 10 minutes of preincubation of the sample with alkaline buffer incorporating with either SDS or potassium ferricyanide before starting the Jaffé reaction was the appropriate way to overcome unconjugated bilirubin interference at a level of 342.0 μmol/L. However, the technique did not work uniformly with icteric patient sera containing conjugated, unconjugated, and delta bilirubin. This is a challenging problem that remains to be solved by the clinical chemist. © 1994 Wiley‐Liss, Inc. Copyright © 1994 Wiley Periodicals, Inc., A Wiley Companyen_US
dc.identifier.citationJournal of Clinical Laboratory Analysis. Vol.8, No.6 (1994), 391-399en_US
dc.identifier.doi10.1002/jcla.1860080609en_US
dc.identifier.issn10982825en_US
dc.identifier.issn08878013en_US
dc.identifier.other2-s2.0-0028019896en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/9529
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0028019896&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectHealth Professionsen_US
dc.subjectMedicineen_US
dc.titleComparison of techniques for minimizing interference of bilirubin on serum creatinine determined by the kinetic Jaffé reactionen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0028019896&origin=inwarden_US

Files