Publication:
Accuracy of cytotechnologist evaluation of specimen adequacy and screening interpretation of malignancy in fine-needle aspiration of the liver

dc.contributor.authorAadil Ahmeden_US
dc.contributor.authorAnna B. Novaken_US
dc.contributor.authorAisha Farhat Sheerinen_US
dc.contributor.authorThiraphon Boonyaarunnateen_US
dc.contributor.authorSyed Z. Alien_US
dc.contributor.authorMatthew T. Olsonen_US
dc.contributor.otherJohns Hopkins Universityen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-11-09T02:32:33Z
dc.date.available2018-11-09T02:32:33Z
dc.date.issued2014-11-07en_US
dc.description.abstract© 2014 S. Karger AG, Basel. Objective: To evaluate the performance of cytotechnologists in assessing the adequacy and accuracy of the preliminary diagnosis for fine-needle aspirates of the liver. Study Design: We retrospectively analyzed 10 years of data and found 589 cases of ultrasound-guided fine-needle aspiration (FNA) of the liver with on-site evaluation of adequacy (OSEA). All the OSEA were performed by the cytopathologist because OSEA of liver FNA is not performed by cytotechnologists at our institution at present. After OSEA, the material was seen by cytotechnologists who rendered an adequacy assessment and preliminary diagnosis. We calculated the adequacy and accuracy statistics and compared the performance of the cytotechnologists with the OSEA and final interpretation. Results: There was no statistically significant difference in adequacy downgrade rate for cytotechnologist versus cytopathologist assessment during the study period (5 vs. 3%, p = 0.06). A total agreement of 88% was noted in overall diagnosis with 97% agreement in malignant cases. Conclusion: Cytotechnologists assess the adequacy of liver FNA accurately and there is therefore potential for them to perform OSEA for liver FNA.en_US
dc.identifier.citationActa Cytologica. Vol.58, No.4 (2014), 367-372en_US
dc.identifier.doi10.1159/000364853en_US
dc.identifier.issn19382650en_US
dc.identifier.issn00015547en_US
dc.identifier.other2-s2.0-84908567750en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/34167
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84908567750&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleAccuracy of cytotechnologist evaluation of specimen adequacy and screening interpretation of malignancy in fine-needle aspiration of the liveren_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84908567750&origin=inwarden_US

Files

Collections