Publication:
Development of new, broadly reactive, rapid IgG and IgM lateral flow assays for diagnosis of scrub typhus

dc.contributor.authorSaowaluk Silpasakornen_US
dc.contributor.authorNujorn Srisamuten_US
dc.contributor.authorPattama Ekpoen_US
dc.contributor.authorZhiwen Zhangen_US
dc.contributor.authorChien Chung Chaoen_US
dc.contributor.authorWei Mei Chingen_US
dc.contributor.authorYupin Suputtamongkolen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherNaval Medical Research Centeren_US
dc.contributor.otherFaculty of Medicine, Siriraj Hospital, Mahidol Universityen_US
dc.date.accessioned2018-06-11T04:52:49Z
dc.date.available2018-06-11T04:52:49Z
dc.date.issued2012-07-01en_US
dc.description.abstractWe evaluated the diagnostic accuracy of two broadly reactive rapid immunochromatographic tests (ICTs) for detection of IgM and IgG against Orientia tsutsugamushi by using archived acute-phase serum samples from 102 patients with laboratory-confirmed scrub typhus, and from 62 archived serum samples from patients with other causes of fever as a negative control. These ICTs were constructed by using a mixture of recombinant proteins: 1) C1, a chimeric protein containing epitopes of the 56-kD antigen from Karp and TA763 strains; 2) Ktr56; and 3) Gmr56. Sensitivities of the ICTs for detection of IgM and IgG were 90.2% (95% confidence interval [CI] = 84.4-96.0%) and 86.3% (95% CI = 80.9-93.8%), respectively. Specificities were 85.5% (95% CI = 73.9-92.2%) and 96.8% (95% CI = 90.3-100%), respectively. Both assays were more sensitive and specific than the standard immune immunofluorescence assay for the early diagnosis of scrub typhus. Copyright © 2012 by The American Society of Tropical Medicine and Hygiene.en_US
dc.identifier.citationAmerican Journal of Tropical Medicine and Hygiene. Vol.87, No.1 (2012), 148-152en_US
dc.identifier.doi10.4269/ajtmh.2012.11-0583en_US
dc.identifier.issn00029637en_US
dc.identifier.other2-s2.0-84863741229en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/14298
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84863741229&origin=inwarden_US
dc.subjectImmunology and Microbiologyen_US
dc.subjectMedicineen_US
dc.titleDevelopment of new, broadly reactive, rapid IgG and IgM lateral flow assays for diagnosis of scrub typhusen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84863741229&origin=inwarden_US

Files

Collections