Publication:
Performance evaluation and comparison of the fully automated urinalysis analyzers UX-2000 and Cobas 6500

dc.contributor.authorBongkot Wesarachkittien_US
dc.contributor.authorVaranya Khejonniten_US
dc.contributor.authorBusadee Pratumviniten_US
dc.contributor.authorKanit Reesukumalen_US
dc.contributor.authorSuriya Meepanyaen_US
dc.contributor.authorChanutchaya Pattanavinen_US
dc.contributor.authorPreechaya Wongkrajangen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-12-11T02:23:05Z
dc.date.accessioned2019-03-14T08:04:16Z
dc.date.available2018-12-11T02:23:05Z
dc.date.available2019-03-14T08:04:16Z
dc.date.issued2016-01-01en_US
dc.description.abstract© American Society for Clinical Pathology, 2016. All rights reserved. Objective: To evaluate and compare the performances of the automated urinalysis devices UX-2000 and Cobas 6500. Method: A total of 258 urine specimens were collected from the routine specimen workload. We analyzed all specimens on both automated instruments and recorded the turnaround time from each method. Physical, chemical, and sedimentary urine components were compared between the automated and the manual method for each analyzer. Results: The correlation of urine physical/chemical properties between the 2 instruments was excellent. The Cobas 6500 instrument demonstrated a higher level of agreement for red blood cells (Cobas 6500: R = 0.94; UX-2000: R = 0.78) and white blood cells (Cobas 6500: R = 0.95; UX-2000: R = 0.85). The UX-2000 demonstrated higher sensitivity for small round cells, hyaline casts, pathological casts, and bacteria. The median turnaround time was 1.5 minutes and 8.5 minutes for the Cobas 6500 and UX-2000, respectively. Conclusions: The 2 devices showed similar performance in technical evaluation; they each reduce workload and increase time saving. However, manual examination by technicians is recommended for pathological specimens.en_US
dc.identifier.citationLaboratory Medicine. Vol.47, No.2 (2016), 124-133en_US
dc.identifier.doi10.1093/labmed/lmw002en_US
dc.identifier.issn19437730en_US
dc.identifier.issn00075027en_US
dc.identifier.other2-s2.0-85018340878en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/43185
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85018340878&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.titlePerformance evaluation and comparison of the fully automated urinalysis analyzers UX-2000 and Cobas 6500en_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85018340878&origin=inwarden_US

Files