Publication:
Corrugated sheet of unsintered hydroxyapatite poly-l-lactide for sternal fixation: A preclinical study

dc.contributor.authorHidehito Kurokien_US
dc.contributor.authorHirokuni Araien_US
dc.contributor.authorSmith Srisonten_US
dc.contributor.authorKeiji Oien_US
dc.contributor.authorMakoto Tomitaen_US
dc.contributor.authorTomohiro Mizunoen_US
dc.contributor.otherFaculty of Medicine, Ramathibodi Hospital, Mahidol Universityen_US
dc.contributor.otherTokyo Medical and Dental Universityen_US
dc.date.accessioned2020-03-26T05:04:38Z
dc.date.available2020-03-26T05:04:38Z
dc.date.issued2020-01-01en_US
dc.description.abstract©2020 The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery. Purpose: To stabilize the sternum after median sternotomy, unsintered hydroxyapatite poly-L-lactide (u-HA/PLLA) sternal pins are frequently used in Japan. However, sternal pins are ineffective in the fragile bone marrow. Thus, a corrugated sheet made of u-HA/PLLA was developed as a new sternal fixation device. Methods: To examine the effects of the device, we measured the shear force using a sternal model and cadaver. The shear force of the corrugated sheet, sternal pin, and simple wire was compared. The device size was determined after reviewing the sternal computed tomography (CT) of 128 patients. Results: The shear force of the model with the corrugated sheet (286 [256–295] N) was higher than that with sternal pins (135 [134–139] N, p = 0.03) and simple wire (94 [90–104] N, p = 0.03) at 2-mm displacement. In the cadaver test, the shear force of the sternal halves with the device was about two times higher than that without the device. Retrospective CT showed that 18-mm wide device applies to 99% male and 87% female patients at the fourth intercostal level. Conclusion: The corrugated sheet might provide a stronger fixation effect in the fragile bone marrow. The device width was modified to 18 mm to be applicable for most Japanese patients.en_US
dc.identifier.citationAnnals of Thoracic and Cardiovascular Surgery. Vol.26, No.1 (2020), 40-46en_US
dc.identifier.doi10.5761/atcs.oa.19-00250en_US
dc.identifier.issn21861005en_US
dc.identifier.issn13411098en_US
dc.identifier.other2-s2.0-85079871525en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/53840
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85079871525&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleCorrugated sheet of unsintered hydroxyapatite poly-l-lactide for sternal fixation: A preclinical studyen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85079871525&origin=inwarden_US

Files

Collections