Publication:
Intraoperative transesophageal echocardiography: preliminary experience at Siriraj hospital.

dc.contributor.authorV. Suwanchindaen_US
dc.contributor.authorU. Prakanrattanaen_US
dc.contributor.authorP. Laksanabunsongen_US
dc.contributor.authorT. Subtaweesinen_US
dc.contributor.authorP. Sakiyalaken_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-07-04T06:57:11Z
dc.date.available2018-07-04T06:57:11Z
dc.date.issued1995-09-01en_US
dc.description.abstractIn order to evaluate the result of intraoperative TEE monitoring for cardiothoracic surgery, 113 patients were involved in this study. They included 65 males and 48 females, with an average age of 48.8 +/- 16.6 years, ranging from 10 to 74 years. The pre-operative diagnoses consisted of 41.6 per cent coronary artery disease, 34.5 per cent valvular disease, 12.4 per cent congenital heart disease, 8 per cent aortic aneurysm or aortic dissection, and 3.5 per cent of miscellaneous. The TEE appeared to provide accurate information by beating to changes in the left ventricular preload and contractility in all patients. The severity of valvular dysfunction, intracardiac air/mass, Swan Ganz catheter position, sites of congenital heart defect and aortic dissection were either assessed or reconfirmed during the operation. The ease of TEE technique was satisfactory, since unsuccessful attempt was observed in only 1.8 per cent. One patient died from rupture of thoracic aortic dissection which was related to TEE probe insertion. These data suggest the favorable result of intraoperative TEE as a valuable tool for monitoring in cardiothoracic surgery. Although the technique is simple, special precaution must be observed for patients suffering from acute aortic dissection.en_US
dc.identifier.citationJournal of the Medical Association of Thailand. Vol.78, No.9 (1995), 487-491en_US
dc.identifier.issn01252208en_US
dc.identifier.other2-s2.0-0029372457en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/17395
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0029372457&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleIntraoperative transesophageal echocardiography: preliminary experience at Siriraj hospital.en_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0029372457&origin=inwarden_US

Files

Collections