dc.description.abstractThe purpose of this in vitro study was to compare the shear bond strength of different types of sealant to non-contaminated and saliva-contaminated enamel. The buccal surfaces of 60 sound permanent third molars were individually embedded in self-curing acrylic resin and wet ground with 1,000-grit silicone carbide paper to obtain a flat enamel surface. The specimens were randomly assigned to one of three groups: 1) non-fluoride-releasing resin sealant (Concise™), 2) fluoridereleasing resin sealant (Clinpro™), 3) glass-ionomer sealant (Fuji VII®). Each group was divided into 2 subgroups (n=10): non-contaminated and saliva contaminated with 0.02 ml of fresh human saliva for 20 seconds and then blowed dried prior to sealant placement. All samples were thermocycled 2,000 cycles. The specimens were tested using an Instron running at a crosshead speed of 0.05 mm/min. Stereomicroscope examinations were carried out to evaluate failure sites of the sealants. Data were analyzed with one-way ANOVA and the Turkey test at a siginificance level of p < 0.05. Comparison of the different types of sealant revealed the shear bond strength of the glass-ionomer sealant was the same for the non-contaminated and salivacontaminated subgroups. The shear bond strength was lower in both the fluoride and non-fluoride releasing resin-based sealant groups contaminated with saliva than in the fluoride and non-fluoride releasing resin-based sealant groups not contaminated with saliva. Comparison of the different types of sealant also revealed the shear bond strength of the glass-ionomer sealant had a significantly lower shear bond strength than the fluoride and non-fluoride releasing resin-based sealant groups for both the non-contaminated and saliva-contaminated subgroups. The fluoride and non-fluoride releasing resin-based sealant groups were not significantly different from each other. The modes of failure were mostly mixed with the glass-ionomer sealant in both the non-contaminated and saliva-contaminated subgroups of this sealant. The resin-based sealant groups (both fluoride and non-fluoride releasing) had cohesive/mixed failure in the non-contaminated and adhesive/mixed failure in the saliva-contaminated subgroups. In conclusion, saliva-contamiantion did not affect the shear bond strength of glass-ionomer sealant but the glass-ionomer sealant had the lowest shear bond strength.en_US
dc.identifier.citationSoutheast Asian Journal of Tropical Medicine and Public Health. Vol.42, No.2 (2011), 463-467en_US
dc.identifier.issn01251562en_US
dc.identifier.other2-s2.0-80051569082en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/12594
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=80051569082&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleShear bond strength of some sealants under saliva contaminationen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=80051569082&origin=inwarden_US

Files

Collections