Publication: The effect of denture cleansing solutions on the retention of Pink Locator® attachment: 1 year simulation.
dc.contributor.author | Pijitra Watcharapichat | en_US |
dc.contributor.author | พิจิตรา วัชราภิชาต | en_US |
dc.contributor.author | Chatchai Kunavisarut | en_US |
dc.contributor.author | ชัชชัย คุณาวิศรุต | en_US |
dc.contributor.author | Piyapanna Pittayachawan | en_US |
dc.contributor.author | ปิยพรรณา พิทยชวาล | en_US |
dc.contributor.author | Tassanee Tengrangsan | en_US |
dc.contributor.author | ทัศนีย์ เต็งรังสรรค์ | en_US |
dc.contributor.correspondence | Chatchai Kunavisarut | en_US |
dc.contributor.correspondence | ชัชชัย คุณาวิศรุต | en_US |
dc.contributor.other | Mahidol University. Faculty of Dentistry. Implant Center | en_US |
dc.contributor.other | Mahidol University. Faculty of Dentistry. Advanced General Dentistry Department | en_US |
dc.date.accessioned | 2015-01-28T07:31:37Z | |
dc.date.accessioned | 2017-01-05T08:27:41Z | |
dc.date.available | 2015-01-28T07:31:37Z | |
dc.date.available | 2017-01-05T08:27:41Z | |
dc.date.created | 2014-01-07 | |
dc.date.issued | 2014-09 | |
dc.description.abstract | Objective: To evaluate the effect of various denture cleansing solutions on retention of pink Locator® attachments after 1 year Materials and methods: Thirty-five pink Locator® attachments (3.0 lbs. Light Retention) were divided into five groups (seven specimens in each group) and soaked in different denture cleansers for 1 year. They were Polident® 5 minutes, Fittydent® , 0.12% Chlorhexidine gluconate, 1% sodium hypochlorite and tap water as control. The pink Locator® attachment was tested for load-to-dislodgement (retentive force; Newton) on a Universal Testing Machine (Model 5566, Instron Corp, Norwood, MA) in separate soaking time (before soaking, after simulated soaking for 1 month, 6 months and 1 year). The percentage of retention loss after soaking in the denture cleansers for 1 month, 6 months and 1 year were compared by groups using the Kruskal-Wallis Test and then followed by the Mann-Whitney U Test to indicate which pairs of denture cleansers were different. A p-value ≤ 0.05 was considered significant. Results: After 1 month soaking time, there was no significant difference among the cleansers (p-value > 0.05). After 6-month soaking time, the retention for attachments soaked in Fittydent® (median of % retention loss: -33.49%) and Chlorhexidine gluconate (-27.05%) were significantly higher than that soaked in tap water (3.81%). There was no significant difference among tap water, Polident® 5 minutes (-8%) and Sodium hypochlorite (-9.57%). After 1-year soaking time, the retention for attachments soaked in Sodium hypochlorite (42.58%) was significantly lower than that soaked in other solutions. The retention for attachments soaked in Fittydent® (-36.04% ) and Chlorhexidine gluconate (-29.03%) were significantly higher than that soaked in tap water (-10.15%). There was no significant difference between tap water and Polident® 5 minutes (-12.41%). Conclusion: Polident® 5 minutes had no significant effect on the retention of pink Locator® . Fittydent® and Chlorhexidine gluconate significantly increased the retention of the attachments. Sodium hypochlorite significantly decreased the retention, thus it should not be recommended as a routine denture cleanser. | en_US |
dc.identifier.citation | Watcharapichat P, Kunavisarut C, Pittayachawan P, Tengrangsan T. The effect of denture cleansing solutions on the retention of pink Locator® attachment: 1 year simulation. M Dent J. 2014; 34(3): 204-14. | en_US |
dc.identifier.issn | 0125-5614 (printed) | |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/1125 | |
dc.language.iso | eng | en_US |
dc.rights | Mahidol University | en_US |
dc.rights.holder | Faculty of Dentistry Mahidol University | en_US |
dc.subject | Dental implants | en_US |
dc.subject | Denture cleansing solutions | en_US |
dc.subject | Locator® attachment | en_US |
dc.subject | Overdenture | en_US |
dc.subject | Retention | en_US |
dc.subject | Open Access article | en_US |
dc.subject | วิทยาสารทันตแพทยศาสตร์มหิดล | |
dc.subject | Mahidol Dental Journal | |
dc.title | The effect of denture cleansing solutions on the retention of Pink Locator® attachment: 1 year simulation. | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mods.location.url | http://www.dt.mahidol.ac.th/division/offeducation/education_1_6/wittayasarn/34-vol.3-2557/34-vol.3-%E0%B8%81%E0%B8%B1%E0%B8%99%E0%B8%A2%E0%B8%B2%E0%B8%A2%E0%B8%99-%E0%B8%98%E0%B8%B1%E0%B8%99%E0%B8%A7%E0%B8%B2%E0%B8%84%E0%B8%A1-2557/02.pdf |