Publication:
A reverse-flow injection analysis method for the determination of dissolved oxygen in fresh and marine waters

dc.contributor.authorSaowapha Muangkaewen_US
dc.contributor.authorIan D. McKelvieen_US
dc.contributor.authorMichael R. Graceen_US
dc.contributor.authorMongkon Rayanakornen_US
dc.contributor.authorKate Grudpanen_US
dc.contributor.authorJaroon Jakmuneeen_US
dc.contributor.authorDuangjai Nacaprichaen_US
dc.contributor.otherChiang Mai Universityen_US
dc.contributor.otherMonash Universityen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-07-24T02:58:24Z
dc.date.available2018-07-24T02:58:24Z
dc.date.issued2002-12-06en_US
dc.description.abstractA reverse flow injection method (rFIA) based on the Winkler titration chemistry, is reported for the determination of dissolved oxygen (DO) in natural waters. Manganese(II) sulfate is injected into a continuously flowing stream of sample and subsequently merges with a reagent stream of sodium hydroxide and sodium iodide. Manganese(II) hydroxide that is formed reacts with DO in the sample to form an oxidized manganese hydroxyoxide floc, Addition of 10% sulfuric acid dissolves this floc, and under acidic conditions, the triiodide ion formed is detected by photometry in a flow through cell at a wavelength of 440 nm. The method is rapid (48 measurements per h), repeatable (R.S.D. ca. 3%, n = 3), and has a calculated detection limit of 0.25 mg l-1(P = 0.001). No interference from nitrite or ferrous ions was observed at concentrations typically found in natural waters. The method has been successfully applied to on-line measurement of DO in sediment respiration reactors. © 2002 Elsevier Science B.V. All rights reserved.en_US
dc.identifier.citationTalanta. Vol.58, No.6 (2002), 1285-1291en_US
dc.identifier.doi10.1016/S0039-9140(02)00414-9en_US
dc.identifier.issn00399140en_US
dc.identifier.other2-s2.0-0038375037en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/20117
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0038375037&origin=inwarden_US
dc.subjectChemistryen_US
dc.titleA reverse-flow injection analysis method for the determination of dissolved oxygen in fresh and marine watersen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0038375037&origin=inwarden_US

Files