dc.description.abstractThis study is a 5- to 11-year retrospective followup of 40 hips in 33 patients with cementless acetabular revision for aseptic failure of a cemented total hip arthroplasty. A porous coated, Harris-Galante acetabular component was used in all revisions. Thirty-eight of the 40 hips received acetabular bone grafting at revision. The mean Harris Hip Score improved from 51 points just before the index cementless revision to 87 points at the most recent followup. Twenty-nine of 40 (73%) hips were classified as having a good or excellent result. Radiolucencies were observed in seven of the 40 (18%) hips at the most recent followup, but none of these radiolucencies were complete or progressive. Five of the 40 (13%) hips were rated as failures and required repeat revision. Two (5%) of these failures were caused by aseptic loosening, with both hips having severe acetabular bone damage at the time of the index revision. This failure rate for aseptic loosening was less than that reported for cemented acetabular revision, thereby confirming the efficacy of cementless acetabular components in revision hip surgery in the intermediate term.en_US
dc.identifier.citationClinical Orthopaedics and Related Research. No.361 (1999), 140-149en_US
dc.identifier.doi10.1097/00003086-199904000-00019en_US
dc.identifier.issn0009921Xen_US
dc.identifier.other2-s2.0-0032901202en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/25761
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0032901202&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleCementless acetabular revision for aseptic failure of cemented hip arthroplastyen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=0032901202&origin=inwarden_US

Files

Collections