Publication:
Development of a modified 100-gram oral glucose tolerance test for diagnosis of gestational diabetes mellitus and its diagnostic accuracy

dc.contributor.authorPornpimol Ruangvutilerten_US
dc.contributor.authorPiya Chaemsaithongen_US
dc.contributor.authorKasem Ruangrongmorakoten_US
dc.contributor.authorSujin Kanokpongsakdien_US
dc.contributor.authorPrasert Sunsaneevithayakulen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherSrinakharinwirot Universityen_US
dc.date.accessioned2018-09-24T09:37:25Z
dc.date.available2018-09-24T09:37:25Z
dc.date.issued2010-01-01en_US
dc.description.abstractObjective: To develop a modified 100-g oral glucose tolerance test (100-g OGTT) for the diagnosis of gestational diabetes mellitus (GDM) in order to reduce the number of values needed for the test. Materials and Methods: Patient charts of pregnant women who completed the 100-g OGTT test at the antenatal clinic, Siriraj Hospital between 2005 and 2006 were reviewed. Cases diagnosed with GDM using standard 100-g OGTT were selected. In non-GDM cases, the last 100-g OGTT test was selected. Diagnostic performances of each glucose value and two or three values in various combinations were determined. Results: One thousand seven hundred sixty three women completed GDM diagnosis throughout their pregnancy. Four hundred three women had GDM while 1,360 subjects were non-GDM. Considering single glucose values, the highest level of accuracy, and the best ROC curve were obtained from the value at 2 hours after glucose ingestion (2-h glucose value) with 93.00% accuracy and the area under the ROC curve of 0.961. The combination of 2-h glucose value with fasting plasma glucose (FPG) showed 93.25% accuracy. FPG combined with 1-h and 2-h glucose values achieved 100% sensitivity with 92% accuracy. Conclusion: FPG in combined with 1-h and 2-h glucose values is an interesting alternative for the diagnosis of GDM.en_US
dc.identifier.citationJournal of the Medical Association of Thailand. Vol.93, No.10 (2010), 1121-1127en_US
dc.identifier.issn01252208en_US
dc.identifier.issn01252208en_US
dc.identifier.other2-s2.0-77958112410en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/29863
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77958112410&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleDevelopment of a modified 100-gram oral glucose tolerance test for diagnosis of gestational diabetes mellitus and its diagnostic accuracyen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77958112410&origin=inwarden_US

Files

Collections