Publication:
A novel paper-based colorimetry device for the determination of the albumin to creatinine ratio

dc.contributor.authorSudkate Chaiyoen_US
dc.contributor.authorKurt Kalcheren_US
dc.contributor.authorAmara Apiluxen_US
dc.contributor.authorOrawon Chailapakulen_US
dc.contributor.authorWeena Siangprohen_US
dc.contributor.otherChulalongkorn Universityen_US
dc.contributor.otherKarl-Franzens-Universitat Grazen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherSrinakharinwirot Universityen_US
dc.date.accessioned2019-08-23T10:25:50Z
dc.date.available2019-08-23T10:25:50Z
dc.date.issued2018-11-21en_US
dc.description.abstract© 2018 The Royal Society of Chemistry. A novel paper-based analytical device (PAD) was fabricated and developed for the simple and rapid determination of the albumin to creatinine ratio (ACR) in urine samples. The detection was based on a colorimetric reaction using bromocresol green (BG) in a phosphate buffer (PB) at pH 4 for the determination of albumin (AL) and creatinine (CR). BG changes color from greenish-yellow to bluish-green in the presence of AL and/or CR. Picric acid (PA) in 0.25 M NaOH was used to detect CR, and PA changes color from yellow to orange. Under the optimal conditions, the working range was 10 to 350 mg dL-1 with a detection limit of 7.1 and 5.4 mg dL-1 for AL + CR and CR detection, respectively. The repeatability was evaluated, and the %RSD value was less than 8.23 (n = 10). The ACR was obtained by calculating the AL and CR colorimetric results. Finally, the proposed devices were applied to the determination of AL, CR, and ACR in urine samples. The results obtained by the developed PADs were in good agreement with the standard method and demonstrated the method could reliably measure AL, CR, and ACR. The proposed method provides a low-cost, simple, sensitive, and promising tool for diagnostic identification assay for chronic kidney disease (CKD).en_US
dc.identifier.citationAnalyst. Vol.143, No.22 (2018), 5453-5460en_US
dc.identifier.doi10.1039/c8an01122ben_US
dc.identifier.issn13645528en_US
dc.identifier.issn00032654en_US
dc.identifier.other2-s2.0-85056148744en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/44996
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85056148744&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectChemistryen_US
dc.subjectEnvironmental Scienceen_US
dc.titleA novel paper-based colorimetry device for the determination of the albumin to creatinine ratioen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85056148744&origin=inwarden_US

Files

Collections