Publication:
Efficacy of fetal echocardiography and an evaluation of indications

dc.contributor.authorJarupim Soongswangen_US
dc.contributor.authorWiboolphan Thitadiloken_US
dc.contributor.authorPrasert Sunsaneevithayakulen_US
dc.contributor.authorAnuwat Sutanthavibulen_US
dc.contributor.authorPornpimol Ruangvutilerten_US
dc.contributor.authorKanchana Wansaniten_US
dc.contributor.authorKesaree Punleeen_US
dc.contributor.authorSuteera Phrudprisanen_US
dc.contributor.authorCharuwan Kangkakateen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-06-21T08:24:10Z
dc.date.available2018-06-21T08:24:10Z
dc.date.issued2005-08-01en_US
dc.description.abstractFetal echocardiography has been accepted as a prenatal noninvasive diagnostic tool of cardiovascular diseases in fetuses for more than three decades. There are limited data in Thailand. A retrospective study of prenatal, natal and postnatal data of pregnant women who had fetal echocardiography at Siriraj Hospital, Bangkok, Thailand, from January 1999 to July 2005 was conducted. In total, there were 117 pregnant women who had fetal echocardiography under standard indications. Median age of pregnant women was 30.2 (17.3-44.2) years old. Median gestational age at the first fetal echocardiography was 29 (17-40) weeks. Median number of time the women had fetal echocardiography was 1 (1-10). Indications for fetal echocardiography were; obstetricians suspected of fetal cardiovascular diseases, multiple anomalies, family history of congenital heart diseases, chromosome anomalies, hydrops fetalis, and other indications (53.8%, 12%, 11.1%, 8.5%, 8.5% and 6.0% respectively). There were 49 (41.8%) cases who had abnormal cardiovascular problems, i.e., structural heart diseases 26 cases, rhythm disturbance 15 cases, and cardiac masses 8 cases. Upon comparison with postnatal echocardiography and/or autopsy findings, fetal echocardiography had a sensitivity of 96.9%, specificity of 90.6%, and accuracy of 92.8%. There was various degrees of risk to have cardiovascular problems for each of the indication taking fetal echocardiography and postnatal data into consideration. Fetal echocardiography had an impact on the management in 57.3% of cases. Conclusion: Fetal echocardiography is a reliable prenatal diagnostic tool for cardiovascular problems with high accuracy and has an impact on the management at prenatal, natal and postnatal period. Different indications for fetal echocardiography have an effect on the relative risk of fetal cardiovascular diseases.en_US
dc.identifier.citationJournal of the Medical Association of Thailand. Vol.88, No.SUPPL. 8 (2005)en_US
dc.identifier.issn01252208en_US
dc.identifier.issn01252208en_US
dc.identifier.other2-s2.0-31744443758en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/16858
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=31744443758&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleEfficacy of fetal echocardiography and an evaluation of indicationsen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=31744443758&origin=inwarden_US

Files

Collections