Publication: Anatomical study of quadriceps tendon for anterior cruciate ligament reconstruction
dc.contributor.author | Thanathep Tanpowpong | en_US |
dc.contributor.author | Teerachat Tanasansomboon | en_US |
dc.contributor.author | Thanasil Huanmanop | en_US |
dc.contributor.author | Sorawut Thamyongkit | en_US |
dc.contributor.author | Peeradon Jaruprat | en_US |
dc.contributor.author | Tharit Inkaratana | en_US |
dc.contributor.other | Chulalongkorn University | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.date.accessioned | 2020-08-25T09:01:01Z | |
dc.date.available | 2020-08-25T09:01:01Z | |
dc.date.issued | 2020-10-01 | en_US |
dc.description.abstract | © 2019 2019 Thanathep Tanpowpong et al., published by Sciendo. The quadriceps tendon is a promising alternative graft choice for anterior cruciate ligament (ACL) reconstruction. Morphology of the graft directly affects the biomechanical properties. However, a few studies are evaluating the anatomical structures of quadriceps tendon as a graft in Asian population. To define the anatomical structures of quadriceps tendon as a graft for ACL reconstruction. Forty-nine quadriceps tendons were dissected and analyzed. Measurements were also done including length, width, and thickness. The maximum length of superficial quadriceps tendon was 63.2 ± 12.5 mm (range 37.6-83.4). The maximum length of tendon at the deepest part was 57.2 ± 11.5 (range 30.9-83.4). The maximum length of quadriceps tendon was located at 61.4% ± 13% (range 31.8-83.6) from medial edge of the patella insertion (approximately 5 mm lateral from the center of quadriceps tendon insertion). The width of quadriceps tendon at patella insertion was 42.4 ± 3.8 mm (range 33.8-50.5). The thickness of quadriceps tendon at its maximum length on patella insertion was 6.9 ± 2.0 mm (range 1.5-9.5). Positive correlation between the height of cadaver and the maximum length of quadriceps tendon was noted. The maximum length of quadriceps tendon was located 5 mm lateral from the center of quadriceps tendon insertion. Thus, we recommend marking midline of the quadriceps tendon insertion as a medial border of the harvested graft to get maximum length of the graft. Graft length measurement using superficial anatomy should be cautioned because graft shortening might occur. | en_US |
dc.identifier.citation | Asian Biomedicine. Vol.13, No.5 (2020), 179-183 | en_US |
dc.identifier.doi | 10.1515/abm-2019-0058 | en_US |
dc.identifier.issn | 1875855X | en_US |
dc.identifier.issn | 19057415 | en_US |
dc.identifier.other | 2-s2.0-85086357954 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/123456789/57674 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85086357954&origin=inward | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.title | Anatomical study of quadriceps tendon for anterior cruciate ligament reconstruction | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85086357954&origin=inward | en_US |