Publication:
Anatomical study of quadriceps tendon for anterior cruciate ligament reconstruction

dc.contributor.authorThanathep Tanpowpongen_US
dc.contributor.authorTeerachat Tanasansomboonen_US
dc.contributor.authorThanasil Huanmanopen_US
dc.contributor.authorSorawut Thamyongkiten_US
dc.contributor.authorPeeradon Jarupraten_US
dc.contributor.authorTharit Inkaratanaen_US
dc.contributor.otherChulalongkorn Universityen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2020-08-25T09:01:01Z
dc.date.available2020-08-25T09:01:01Z
dc.date.issued2020-10-01en_US
dc.description.abstract© 2019 2019 Thanathep Tanpowpong et al., published by Sciendo. The quadriceps tendon is a promising alternative graft choice for anterior cruciate ligament (ACL) reconstruction. Morphology of the graft directly affects the biomechanical properties. However, a few studies are evaluating the anatomical structures of quadriceps tendon as a graft in Asian population. To define the anatomical structures of quadriceps tendon as a graft for ACL reconstruction. Forty-nine quadriceps tendons were dissected and analyzed. Measurements were also done including length, width, and thickness. The maximum length of superficial quadriceps tendon was 63.2 ± 12.5 mm (range 37.6-83.4). The maximum length of tendon at the deepest part was 57.2 ± 11.5 (range 30.9-83.4). The maximum length of quadriceps tendon was located at 61.4% ± 13% (range 31.8-83.6) from medial edge of the patella insertion (approximately 5 mm lateral from the center of quadriceps tendon insertion). The width of quadriceps tendon at patella insertion was 42.4 ± 3.8 mm (range 33.8-50.5). The thickness of quadriceps tendon at its maximum length on patella insertion was 6.9 ± 2.0 mm (range 1.5-9.5). Positive correlation between the height of cadaver and the maximum length of quadriceps tendon was noted. The maximum length of quadriceps tendon was located 5 mm lateral from the center of quadriceps tendon insertion. Thus, we recommend marking midline of the quadriceps tendon insertion as a medial border of the harvested graft to get maximum length of the graft. Graft length measurement using superficial anatomy should be cautioned because graft shortening might occur.en_US
dc.identifier.citationAsian Biomedicine. Vol.13, No.5 (2020), 179-183en_US
dc.identifier.doi10.1515/abm-2019-0058en_US
dc.identifier.issn1875855Xen_US
dc.identifier.issn19057415en_US
dc.identifier.other2-s2.0-85086357954en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/57674
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85086357954&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.titleAnatomical study of quadriceps tendon for anterior cruciate ligament reconstructionen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85086357954&origin=inwarden_US

Files

Collections