Publication:
An automated in-chip-catalytic-spectrophotometric method for determination of copper(ii) using a multisyringe flow injection analysis-multipumping flow system

dc.contributor.authorPiyawan Phansien_US
dc.contributor.authorCamelia Henríquezen_US
dc.contributor.authorEdwin Palacioen_US
dc.contributor.authorDuangjai Nacaprichaen_US
dc.contributor.authorVíctor Cerdàen_US
dc.contributor.otherFlow Innovation-Research for Science and Technology Laboratories (FIRST Labs.en_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherUniversitat de les Illes Balearsen_US
dc.date.accessioned2018-11-09T02:04:21Z
dc.date.available2018-11-09T02:04:21Z
dc.date.issued2014-01-01en_US
dc.description.abstract© the Partner Organisations 2014. In this work a fully automated catalytic-spectrophotometric method for determination of copper at trace levels using a multisyringe flow injection system (MSFIA) and a multipumping flow system (MPFS) coupled to a micro-chip (Chip-MSFIA-MPFS) is presented. The reaction is based on the catalytic effect of Cu(ii) on the oxidation of the in situ reduced form of 2,6-dichlorophenolindophenol (DCPI)r, by hydrogen peroxide. Due to the importance of the mixing order of the reagents, a new design of the chip is proposed. DCPI, ascorbic acid and buffer are first propelled to mix in the front section of the chip using MPFS. Then this reagent mixture, together with hydrogen peroxide and the sample, is simultaneously dispensed to the rear section of the chip by using a multisyringe for mixing, heating and absorbance measurement of the product at 600 nm. The optimum conditions are 0.9 mmol L-1 DCPI, 3.6 mmol L-1 ascorbic acid, 0.8 mol L-1 ammonium chloride buffer, pH 10.5, and 0.3 mol L-1 H2O2. The proposed system is simple, rapid, selective and sensitive. We can determine trace levels of Cu(ii) at room temperature (25 °C). The main analytical characteristics of the proposed method are a detection limit of 0.12 μg L-1 of Cu(ii), a working range of 0.4-35.0 μg L-1 of Cu(ii), and a relative standard deviation of 0.79% (10 μg L-1 Cu(ii), n = 15). The system was successfully applied to water samples, certified reference materials (CRMs) of river and waste water, acid digested multivitamins and animal tissues with a sample throughput of 31 injections h-1. This journal isen_US
dc.identifier.citationAnalytical Methods. Vol.6, No.21 (2014), 8494-8504en_US
dc.identifier.doi10.1039/c4ay01499een_US
dc.identifier.issn17599679en_US
dc.identifier.issn17599660en_US
dc.identifier.other2-s2.0-84908012833en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/33601
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84908012833&origin=inwarden_US
dc.subjectChemical Engineeringen_US
dc.subjectChemistryen_US
dc.subjectEngineeringen_US
dc.titleAn automated in-chip-catalytic-spectrophotometric method for determination of copper(ii) using a multisyringe flow injection analysis-multipumping flow systemen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84908012833&origin=inwarden_US

Files

Collections