dc.description.abstract© 2018, Springer-Verlag GmbH Germany, part of Springer Nature. Introduction: To investigate the validity of Barthel Index (BI) compared with de Morton Mobility Index (DEMMI), EuroQol-visual analog scale (EQ-VAS), 2-min walk test (2MWT), and timed get-up-and-go test (TUG), and to evaluate the responsiveness of all outcome measures for assessing functional recovery in older patients who underwent hemiarthroplasty after femoral neck fracture. Material and method: Eighty-one femoral neck fracture patients who were enrolled in a study evaluating functional recovery after bisphosphonate therapy during 2013 to 2015, and who had data available at both baseline and 12 months after surgery were included in this study. Results: All scores improved significantly from baseline to the 1-year follow-up. BI had moderate to strong correlation with DEMMI, 2MWT, and TUG (r-value: 0.490–0.843), and mild to moderate correlation with EQ-VAS (r-value: 0.278–0.323). All outcome measurements had high effect estimates. The minimal clinically important difference (MCID) of BI at 12 months was 9.8 points. Conclusion: Since BI was shown to have good validity (moderate to strong correlation with DEMMI and performance-based tests, and mild to moderate correlation with EQ-VAS), BI can be used to accurately assess functional recovery in patients who undergo hemiarthroplasty after femoral neck fracture.en_US
dc.identifier.citationArchives of Orthopaedic and Trauma Surgery. Vol.138, No.12 (2018), 1671-1677en_US
dc.identifier.doi10.1007/s00402-018-3020-zen_US
dc.identifier.issn14343916en_US
dc.identifier.issn09368051en_US
dc.identifier.other2-s2.0-85052569978en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/46152
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85052569978&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleValidity and responsiveness of Barthel index for measuring functional recovery after hemiarthroplasty for femoral neck fractureen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85052569978&origin=inwarden_US

Files

Collections