Publication: Intravesical knotting of a feeding tube used as a urinary catheter
dc.contributor.author | Phichaya Sujijantararat | en_US |
dc.contributor.other | Mahidol University | en_US |
dc.date.accessioned | 2018-08-24T02:05:04Z | |
dc.date.available | 2018-08-24T02:05:04Z | |
dc.date.issued | 2007-06-01 | en_US |
dc.description.abstract | Urethral catheterization is a common procedure among pediatric patients. Intravesical knotting of a polyethylene feeding tube used as a urethral catheter is rare. This report described such a complication in an infant who had urethral catheterization with 5 Fr feeding tube. Removal of the catheter necessitated cystotomy. This complication is preventable if the feeding tube is inserted only as short as possible to retrieve urine. | en_US |
dc.identifier.citation | Journal of the Medical Association of Thailand. Vol.90, No.6 (2007), 1231-1233 | en_US |
dc.identifier.issn | 01252208 | en_US |
dc.identifier.issn | 01252208 | en_US |
dc.identifier.other | 2-s2.0-34347362887 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/123456789/24857 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=34347362887&origin=inward | en_US |
dc.subject | Medicine | en_US |
dc.title | Intravesical knotting of a feeding tube used as a urinary catheter | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=34347362887&origin=inward | en_US |