Publication:
Affordable, Reliable Dual-Platform Approach to Quantitating Phosphatidylserine-Exposing Platelets in Platelet Components

dc.contributor.authorEgarit Noulsrien_US
dc.contributor.authorSurada Lerdwanaen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherFaculty of Medicine, Siriraj Hospital, Mahidol Universityen_US
dc.date.accessioned2020-03-26T04:29:57Z
dc.date.available2020-03-26T04:29:57Z
dc.date.issued2020-03-10en_US
dc.description.abstract© American Society for Clinical Pathology 2019. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com. OBJECTIVE: To compare the number of phosphatidylserine (PS)-exposing platelets obtained using the dual-platform approach and bead-based flow cytometry. METHODS: Platelets were enumerated using the ADVIA 2010i instrument (Siemens AG). The numbers and percentages of PS-exposing platelets in 175 platelet products were determined using a FACSCalibur flow cytometer (Becton, Dickinson and Company) and counting beads. RESULTS: Our results showed good correlation (r2 = 0.96; P <.001) between the PS-exposing platelets obtained using counting beads and the dual-platform approach. The results of Bland-Altman analysis showed a bias of +46,449 cells per µL and a limit of agreement (LOA) from -197,863 to 290,762 cells per µL. Also, 8 measurements (5.0%) revealed a number of PS-exposing platelets outside the LOA ranges. Further, 21 measurements (12.0%) revealed greater than 2-fold changes in the number of PS-exposing platelets. CONCLUSIONS: The results suggest that the dual-platform approach is affordable and reliable for quantitating PS-exposing platelets as part of monitoring the quality of platelet products.en_US
dc.identifier.citationLaboratory medicine. Vol.51, No.2 (2020), 186-192en_US
dc.identifier.doi10.1093/labmed/lmz048en_US
dc.identifier.issn19437730en_US
dc.identifier.other2-s2.0-85081942568en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/53567
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85081942568&origin=inwarden_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectMedicineen_US
dc.titleAffordable, Reliable Dual-Platform Approach to Quantitating Phosphatidylserine-Exposing Platelets in Platelet Componentsen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85081942568&origin=inwarden_US

Files

Collections