Publication: Comparison of mean centering of ratio spectra based spectrophotometric approach and HPLC method for quantitative determination of pirenoxine in the presence of methylparaben and propylparaben
4
Issued Date
2018-04-01
Resource Type
ISSN
00195464
Other identifier(s)
2-s2.0-85049618473
Rights
Mahidol University
Rights Holder(s)
SCOPUS
Bibliographic Citation
Indian Journal of Pharmaceutical Education and Research. Vol.52, No.2 (2018), 284-292
Suggested Citation
Hendri Wasito, Sawanya Buranaphalin, Lawan Sratthaphut, Leena Suntornsuk, Prapin Wilairat, Chutima Matayatsuk Phechkrajang Comparison of mean centering of ratio spectra based spectrophotometric approach and HPLC method for quantitative determination of pirenoxine in the presence of methylparaben and propylparaben. Indian Journal of Pharmaceutical Education and Research. Vol.52, No.2 (2018), 284-292. doi:10.5530/ijper.52.2.33 Retrieved from: https://repository.li.mahidol.ac.th/handle/123456789/47318
Research Projects
Organizational Units
Authors
Journal Issue
Thesis
Title
Comparison of mean centering of ratio spectra based spectrophotometric approach and HPLC method for quantitative determination of pirenoxine in the presence of methylparaben and propylparaben
Other Contributor(s)
Abstract
© 2018, Association of Pharmaceutical Teachers of India. All rights reserved. Objective: The mean centering of ratio spectra method (MCR) was developed for determination of pirenoxine in the presence of methylparaben and propylparaben. Background: The UV spectrum of pirenoxine was suffered from spectra overlapping of methylparaben and propylparaben, the preservatives used in the eye drop formulation. Since, MCR method was introduced to overcome this limitation. Methods: The developed MCR method was performed using 39 synthetic mixtures of pirenoxine, methylparaben and propylparaben. The amplitudes at 320 nm of the second ratio spectra were used to construct a calibration model for pirenoxine. Performance characteristics of the method such as linearity, accuracy and precision, were calculated. A high-performance liquid chromatography (HPLC) method was also developed and validated. Then, two methods were used to determine a set of commercial eye drop samples for comparison. Results: The developed and validated MCR method was simple, rapid, accurate, and precise and could be applied to determine pirenoxine in eye drop samples. Measurement of pirenoxine in eye drop samples by MCR and HPLC methods were not significantly different (P-value = 0.21).
