Publication:
Loop-mediated isothermal PCR (LAMP) for the diagnosis of falciparum malaria

dc.contributor.authorDaniel H. Parisen_US
dc.contributor.authorMallika Imwongen_US
dc.contributor.authorAbul M. Faizen_US
dc.contributor.authorMahtabuddin Hasanen_US
dc.contributor.authorEmran Bin Yunusen_US
dc.contributor.authorKamolrat Silamuten_US
dc.contributor.authorSue J. Leeen_US
dc.contributor.authorNicholas P J Dayen_US
dc.contributor.authorArjen M. Dondorpen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherFaculty of Tropical Medicineen_US
dc.date.accessioned2018-08-24T01:51:23Z
dc.date.available2018-08-24T01:51:23Z
dc.date.issued2007-11-01en_US
dc.description.abstractA recently described loop-mediated isothermal polymerase chain reaction (LAMP) for molecular detection of Plasmodium falciparum was compared with microscopy, PfHRP2-based rapid diagnostic test (RDT), and nested polymerase chain reaction (PCR) as the "gold standard" in 115 Bangladeshi in-patients with fever. DNA extraction for LAMP was conducted by conventional methods or simple heating of the sample; test results were either assessed visually or by gel electrophoresis. Conventional DNA extraction followed by gel electrophoresis had the highest agreement with the reference method (81.7%, κ = 0.64), with a sensitivity (95% CI) of 76.1% (68.3-83.9%), comparable to RDT and microscopy, but a specificity of 89.6% (84.0-95.2%) compared with 100% for RDT and microscopy. DNA extraction by heat treatment deteriorated specificity to unacceptable levels. LAMP enables molecular diagnosis of falciparum malaria in settings with limited technical resources but will need further optimization. The results are in contrast with a higher accuracy reported in an earlier study comparing LAMP with a non-validated PCR method. Copyright © 2007 by The American Society of Tropical Medicine and Hygiene.en_US
dc.identifier.citationAmerican Journal of Tropical Medicine and Hygiene. Vol.77, No.5 (2007), 972-976en_US
dc.identifier.issn00029637en_US
dc.identifier.other2-s2.0-42949136157en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/24493
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=42949136157&origin=inwarden_US
dc.subjectImmunology and Microbiologyen_US
dc.subjectMedicineen_US
dc.titleLoop-mediated isothermal PCR (LAMP) for the diagnosis of falciparum malariaen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=42949136157&origin=inwarden_US

Files

Collections