Publication:
Comparison of efficacy between 1 mg overnight dexamethasone suppression test and 2-day low dose dexamethasone suppression test for diagnosis of Cushing's syndrome

dc.contributor.authorNuntakorn Kungpanichkulen_US
dc.contributor.authorSathit Vannasaengen_US
dc.contributor.authorN. Thongtangen_US
dc.contributor.otherMahidol Universityen_US
dc.date.accessioned2018-09-24T09:36:06Z
dc.date.available2018-09-24T09:36:06Z
dc.date.issued2010-01-01en_US
dc.description.abstractObjective: To assess the sensitivity and specificity of 1 mg overnight dexamethasone suppression test (ODST) and the 2-day low dose dexamethasone suppression test (LDST) for diagnosis of Cushing's syndrome, and to compare the accuracy of both tests using cutoff value at below 5 μg/dl and at below 1.8 μg/dl. Material and Method: The present study is a retrospective study, from 1971-2007, in one academic center of 77 patients with clinical suspicion of Cushing's syndrome. Kappa statistical analysis was used to determine agreement between the two tests. Sensitivity and specificity of the tests were calculated. ROC curves were created to determine the best cutoff value of the two tests. Results: ODST has very good agreement with the more troublesome LDST and has comparable efficacy. Lowering the cutoff value from 5 μg/dl to 1.8 μg/dl does not improve the accuracy of ODST but results in decreased specificity of LDST. The best cutoff value of ODST test is ≥ 5.3 μg/dl and the best cutoff value of LDST is ≥ 5 μg/dl. Conclusion: ODST is an efficient method for diagnosis of patients suspected of having Cushing's syndrome. The attempt to lowering cutoff value does not improve the efficacy of dexamethasone suppression test.en_US
dc.identifier.citationJournal of the Medical Association of Thailand. Vol.93, No.1 (2010), 27-33en_US
dc.identifier.issn01252208en_US
dc.identifier.issn01252208en_US
dc.identifier.other2-s2.0-77249157381en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/29833
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77249157381&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleComparison of efficacy between 1 mg overnight dexamethasone suppression test and 2-day low dose dexamethasone suppression test for diagnosis of Cushing's syndromeen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77249157381&origin=inwarden_US

Files

Collections