Publication:
Design and Static loading test of AFOs to control foot drop among patients with Peroneal Nerve injury

dc.contributor.authorMay Su Khaingen_US
dc.contributor.authorManunchaya Samalaen_US
dc.contributor.authorGary Guerraen_US
dc.contributor.authorAttaporn Wisessinten_US
dc.contributor.otherKasetsart Universityen_US
dc.contributor.otherFaculty of Medicine Siriraj Hospital, Mahidol Universityen_US
dc.date.accessioned2022-08-04T08:27:51Z
dc.date.available2022-08-04T08:27:51Z
dc.date.issued2021-01-01en_US
dc.description.abstractAnkle foot orthotics can help persons with disabilities such as drop foot to ambulate more optimally. However, before clinical use, the design and static mechanical testing of such devices must occur. The purpose of this study was to design and fabricate an adjustable Posterior Leaf Spring (PLS) ankle-foot orthosis (AFO) and to perform the mechanical static loading test for an Adjustable PLS AFO and traditional flexible AFO. Static mechanical testing (bending test) was performed using an Instron 8801 machine for two different AFO designs; the adjustable PLS AFO and traditional flexible AFO. Both AFOs were made with 5 mm Polypropylene (PP).The posterior bar of PLS AFO was made with 8 mm thick polypropylene (PP), and in traditional AFO, 3 mm PP was added and reinforced before thermoforming with 5 mm PP. The stiffness properties were calculated from the slope of the moment versus angles graph and were as follows: adjustable PLS AFO was 0.4 Nm/ degree to 0.6 Nm/degree, while Traditional flexible AFO has 0.3 Nm/degree to 0.5 Nm/degree. In the same way, adjustable PLS AFO requires the maximum Load (25 to 31 N) for the final displacement when traditional AFO needs 26 N only. The adjustable PLS AFO has higher stiffness properties than the traditional flexible AFO. Future studies are planned to evaluate the lower limb spatiotemporal and sagittal kinematic gait parameters of foot drop patients during walking.en_US
dc.identifier.citationBMEiCON 2021 - 13th Biomedical Engineering International Conference. (2021)en_US
dc.identifier.doi10.1109/BMEiCON53485.2021.9745199en_US
dc.identifier.other2-s2.0-85128179201en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/76692
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85128179201&origin=inwarden_US
dc.subjectComputer Scienceen_US
dc.subjectEngineeringen_US
dc.subjectMaterials Scienceen_US
dc.subjectMedicineen_US
dc.titleDesign and Static loading test of AFOs to control foot drop among patients with Peroneal Nerve injuryen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85128179201&origin=inwarden_US

Files

Collections