Publication:
Quantitative detection of human immunodeficiency virus type 1 (HIV-1) viral load by real-time RT-PCR assay using self-quenched fluorogenic primers

dc.contributor.authorSomying Promsoen_US
dc.contributor.authorChutatip Srichunrusamien_US
dc.contributor.authorKanchala Utiden_US
dc.contributor.authorVeraphong Lulitanonden_US
dc.contributor.authorWantanit Pairojen_US
dc.contributor.authorWasun Chantràtitaen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherKhon Kaen Universityen_US
dc.date.accessioned2018-08-20T07:05:59Z
dc.date.available2018-08-20T07:05:59Z
dc.date.issued2006-12-01en_US
dc.description.abstractHIV-1 viral load is a basic marker to evaluate the severity of HIV-1 related diseases and to monitor the effectiveness of treatment. A method based on real-time RT-PCR technology has been developed to quantify HIV-1 RNA using self-quenched fluorogenic primers known as LUX™ primers. They were used in this study to recognize a low variable gag region of subtype E and B consensus sequences. Specificity was verified by amplicon melting temperatures. An external standard curve was constructed with 10 fold serial dilutions of synthetic HIV-gag RNA. A broad range linear relationship (10 to 106 copies/ml) was observed between the number of PCR cycles needed to detect a fluorescent signal and the number of RNA copies. The intra- and inter-assay coefficients of variation were 0.72 to 2.54% and 3.14 to 8.83%, respectively, thus indicating good reproducibility. Thirty out of fifty HIV-infected individual plasma samples were quantified by this method and compared with the AMPLICOR® HIV-1 Monitor assay, which is widely considered the reference technique for HIV-RNA viral load measurement. The results indicate that the AMPLICOR® HIV-1 Monitor assay and real-time RT-PCR using LUX™ primers are in good agreement (mean difference in log 10 copies/ml ± 2 standard deviations = 0.21 ± 1.34).en_US
dc.identifier.citationSoutheast Asian Journal of Tropical Medicine and Public Health. Vol.37, No.3 (2006), 477-487en_US
dc.identifier.issn01251562en_US
dc.identifier.other2-s2.0-33845746733en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/23441
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33845746733&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleQuantitative detection of human immunodeficiency virus type 1 (HIV-1) viral load by real-time RT-PCR assay using self-quenched fluorogenic primersen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33845746733&origin=inwarden_US

Files

Collections