Publication: Quantitative detection of human immunodeficiency virus type 1 (HIV-1) viral load by real-time RT-PCR assay using self-quenched fluorogenic primers
| dc.contributor.author | Somying Promso | en_US |
| dc.contributor.author | Chutatip Srichunrusami | en_US |
| dc.contributor.author | Kanchala Utid | en_US |
| dc.contributor.author | Veraphong Lulitanond | en_US |
| dc.contributor.author | Wantanit Pairoj | en_US |
| dc.contributor.author | Wasun Chantràtita | en_US |
| dc.contributor.other | Mahidol University | en_US |
| dc.contributor.other | Khon Kaen University | en_US |
| dc.date.accessioned | 2018-08-20T07:05:59Z | |
| dc.date.available | 2018-08-20T07:05:59Z | |
| dc.date.issued | 2006-12-01 | en_US |
| dc.description.abstract | HIV-1 viral load is a basic marker to evaluate the severity of HIV-1 related diseases and to monitor the effectiveness of treatment. A method based on real-time RT-PCR technology has been developed to quantify HIV-1 RNA using self-quenched fluorogenic primers known as LUX™ primers. They were used in this study to recognize a low variable gag region of subtype E and B consensus sequences. Specificity was verified by amplicon melting temperatures. An external standard curve was constructed with 10 fold serial dilutions of synthetic HIV-gag RNA. A broad range linear relationship (10 to 106 copies/ml) was observed between the number of PCR cycles needed to detect a fluorescent signal and the number of RNA copies. The intra- and inter-assay coefficients of variation were 0.72 to 2.54% and 3.14 to 8.83%, respectively, thus indicating good reproducibility. Thirty out of fifty HIV-infected individual plasma samples were quantified by this method and compared with the AMPLICOR® HIV-1 Monitor assay, which is widely considered the reference technique for HIV-RNA viral load measurement. The results indicate that the AMPLICOR® HIV-1 Monitor assay and real-time RT-PCR using LUX™ primers are in good agreement (mean difference in log 10 copies/ml ± 2 standard deviations = 0.21 ± 1.34). | en_US |
| dc.identifier.citation | Southeast Asian Journal of Tropical Medicine and Public Health. Vol.37, No.3 (2006), 477-487 | en_US |
| dc.identifier.issn | 01251562 | en_US |
| dc.identifier.other | 2-s2.0-33845746733 | en_US |
| dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/123456789/23441 | |
| dc.rights | Mahidol University | en_US |
| dc.rights.holder | SCOPUS | en_US |
| dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33845746733&origin=inward | en_US |
| dc.subject | Medicine | en_US |
| dc.title | Quantitative detection of human immunodeficiency virus type 1 (HIV-1) viral load by real-time RT-PCR assay using self-quenched fluorogenic primers | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication | |
| mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33845746733&origin=inward | en_US |
