dc.contributor.authorChusak Kijkunasathianen_US
dc.contributor.authorTeerayut Dechmaneeninen_US
dc.contributor.authorChalermchai Limitlaohaphanen_US
dc.contributor.otherFaculty of Medicine, Ramathibodi Hospital, Mahidol Universityen_US
dc.contributor.otherVejthani Hospitalen_US
dc.date.accessioned2019-08-28T06:20:47Z
dc.date.available2019-08-28T06:20:47Z
dc.date.issued2018-03-01en_US
dc.description.abstract© 2018, Medical Association of Thailand. All rights reserved. Background: The strength of a supraspinatus tendon repair depends on many factors. One factor, the distance from the suture-bite to the lateral edge of the repaired tendon, has never been biomechanically evaluated. Objective: The more medial suture depth to the repaired supraspinatus tendon could obtained the better pull-out strength compared to the lateral suture-depth distance. Materials and Methods: Six paired human supraspinatus tendons were harvested and were randomly assigned to be repaired with Fiberwire® No. 2 at different suture depths (distance from the lateral tendon edge to the suture bite). Biomechanics properties were tested and modes of failure were noted. Results: All characteristics of the tendon specimens were normal. Load to failure was found to be proportional to the suture depth by 19.65 N/mm displacement. A suture depth of 15 mm had the highest load to failure at 275.1±10.5 N(p-value<0.01). The mode of failure in two of the six 15 mm specimens was suture breakage; the remaining four specimens failed at the suture-tendon interface. Conclusion: A suture bite located 15 mm from the lateral tendon edge provides the best possible biomechanical properties with the lowest failure rate. The most common mode offailure is pull-out at the suture-tendon interface.en_US
dc.identifier.citationJournal of the Medical Association of Thailand. Vol.101, No.3 (2018), S75-S79en_US
dc.identifier.issn01252208en_US
dc.identifier.other2-s2.0-85064204500en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/123456789/46881
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85064204500&origin=inwarden_US
dc.subjectMedicineen_US
dc.titleDoes suture depth affect the pull-out strength of supraspinatus repair? A cadaveric modelen_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85064204500&origin=inwarden_US

Files

Collections