Publication: International collaborative study for the calibration of proposed International Standards for thromboplastin, rabbit, plain, and for thromboplastin, recombinant, human, plain
dc.contributor.author | A. M.H.P. van den Besselaar | en_US |
dc.contributor.author | V. Chantarangkul | en_US |
dc.contributor.author | F. Angeloni | en_US |
dc.contributor.author | N. B. Binder | en_US |
dc.contributor.author | M. Byrne | en_US |
dc.contributor.author | R. Dauer | en_US |
dc.contributor.author | B. R. Gudmundsdottir | en_US |
dc.contributor.author | J. Jespersen | en_US |
dc.contributor.author | S. Kitchen | en_US |
dc.contributor.author | C. Legnani | en_US |
dc.contributor.author | T. L. Lindahl | en_US |
dc.contributor.author | R. A. Manning | en_US |
dc.contributor.author | M. Martinuzzo | en_US |
dc.contributor.author | O. Panes | en_US |
dc.contributor.author | V. Pengo | en_US |
dc.contributor.author | A. Riddell | en_US |
dc.contributor.author | S. Subramanian | en_US |
dc.contributor.author | A. Szederjesi | en_US |
dc.contributor.author | C. Tantanate | en_US |
dc.contributor.author | P. Herbel | en_US |
dc.contributor.author | A. Tripodi | en_US |
dc.contributor.other | Imperial College Healthcare NHS Trust | en_US |
dc.contributor.other | Roche Diagnostics GmbH | en_US |
dc.contributor.other | Landspitali University Hospital | en_US |
dc.contributor.other | Szent Laszlo Hospital | en_US |
dc.contributor.other | Università degli Studi di Milano | en_US |
dc.contributor.other | Pontificia Universidad Católica de Chile | en_US |
dc.contributor.other | Alma Mater Studiorum Università di Bologna | en_US |
dc.contributor.other | UCL | en_US |
dc.contributor.other | Leiden University Medical Center - LUMC | en_US |
dc.contributor.other | Faculty of Medicine, Siriraj Hospital, Mahidol University | en_US |
dc.contributor.other | Trinity College Dublin | en_US |
dc.contributor.other | Linköpings universitet | en_US |
dc.contributor.other | Instituto Universitario del Hospital Italiano de Buenos Aires | en_US |
dc.contributor.other | University of Southern Denmark, Esbjerg | en_US |
dc.contributor.other | Royal Hallamshire Hospital | en_US |
dc.contributor.other | St. John's Medical College Hospital | en_US |
dc.contributor.other | Università degli Studi di Padova | en_US |
dc.contributor.other | Technoclone GmbH | en_US |
dc.contributor.other | Fondazione Luigi Villa | en_US |
dc.contributor.other | Hemostasis Reference Laboratory | en_US |
dc.contributor.other | Haematology Department | en_US |
dc.date.accessioned | 2019-08-28T06:40:58Z | |
dc.date.available | 2019-08-28T06:40:58Z | |
dc.date.issued | 2018-01-01 | en_US |
dc.description.abstract | © 2017 International Society on Thrombosis and Haemostasis Essentials Two candidate International Standards for thromboplastin (coded RBT/16 and rTF/16) are proposed. International Sensitivity Index (ISI) of proposed standards was assessed in a 20-centre study. The mean ISI for RBT/16 was 1.21 with a between-centre coefficient of variation of 4.6%. The mean ISI for rTF/16 was 1.11 with a between-centre coefficient of variation of 5.7%. Summary: Background The availability of International Standards for thromboplastin is essential for the calibration of routine reagents and hence the calculation of the International Normalized Ratio (INR). Stocks of the current Fourth International Standards are running low. Candidate replacement materials have been prepared. This article describes the calibration of the proposed Fifth International Standards for thromboplastin, rabbit, plain (coded RBT/16) and for thromboplastin, recombinant, human, plain (coded rTF/16). Methods An international collaborative study was carried out for the assignment of International Sensitivity Indexes (ISIs) to the candidate materials, according to the World Health Organization (WHO) guidelines for thromboplastins and plasma used to control oral anticoagulant therapy with vitamin K antagonists. Results Results were obtained from 20 laboratories. In several cases, deviations from the ISI calibration model were observed, but the average INR deviation attributabled to the model was not greater than 10%. Only valid ISI assessments were used to calculate the mean ISI for each candidate. The mean ISI for RBT/16 was 1.21 (between-laboratory coefficient of variation [CV]: 4.6%), and the mean ISI for rTF/16 was 1.11 (between-laboratory CV: 5.7%). Conclusions The between-laboratory variation of the ISI for candidate material RBT/16 was similar to that of the Fourth International Standard (RBT/05), and the between-laboratory variation of the ISI for candidate material rTF/16 was slightly higher than that of the Fourth International Standard (rTF/09). The candidate materials have been accepted by WHO as the Fifth International Standards for thromboplastin, rabbit plain, and thromboplastin, recombinant, human, plain. | en_US |
dc.identifier.citation | Journal of Thrombosis and Haemostasis. Vol.16, No.1 (2018), 142-149 | en_US |
dc.identifier.doi | 10.1111/jth.13879 | en_US |
dc.identifier.issn | 15387836 | en_US |
dc.identifier.issn | 15387933 | en_US |
dc.identifier.other | 2-s2.0-85036558069 | en_US |
dc.identifier.uri | https://repository.li.mahidol.ac.th/handle/20.500.14594/47254 | |
dc.rights | Mahidol University | en_US |
dc.rights.holder | SCOPUS | en_US |
dc.source.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85036558069&origin=inward | en_US |
dc.subject | Medicine | en_US |
dc.title | International collaborative study for the calibration of proposed International Standards for thromboplastin, rabbit, plain, and for thromboplastin, recombinant, human, plain | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
mu.datasource.scopus | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85036558069&origin=inward | en_US |