Publication:
The influence of organic loading and anoxic/oxic times on the removal of carbon, nitrogen and phosphorus from a wastewater treated in a sequencing batch reactor

dc.contributor.authorP. Fongsatitkulen_US
dc.contributor.authorD. G. Warehamen_US
dc.contributor.authorP. Elefsiniotisen_US
dc.contributor.otherMahidol Universityen_US
dc.contributor.otherUniversity of Canterburyen_US
dc.contributor.otherUniversity of Aucklanden_US
dc.date.accessioned2018-07-12T02:27:32Z
dc.date.available2018-07-12T02:27:32Z
dc.date.issued2008-06-01en_US
dc.description.abstractIn this study, 10 L sequencing batch reactors (SBRs) were operated at a 12-h cycle length (four alternating anoxic/oxic conditions) to assess the biological nutrient removal potential of a domestic wastewater treated at the Huay Kwang plant, Bangkok, Thailand. The wastewater was found to be carbon-limited (chemical oxygen demand (COD) to total Kjeldahl nitrogen (TKN) (i.e., COD:TKN) ratio of 6.4:1). This ratio was insufficient to support good phosphorus removal. Glucose was therefore added to increase the COD:TKN ratio ultimately to 10:1 and the COD, TKN and total phosphorus (TP) removals at this ratio were all in excess of 95%. An alternative carbon source from a local fruit canning industry was then added at the same COD:TKN ratio; and, in order to increase the throughput of the waste treated, the cycle length was simultaneously shortened to 8 h keeping approximately the same anoxic/oxic fractions. The COD removal remained high (>95%), however the TKN and TP removals were substantially reduced (79% and 66%, respectively), indicating that the shortened cycle length was sub-optimum. The last phase of the research involved changing the anoxic/oxic fractions of the cycle time to maximize performance. It was found that for the conditions studied in this research, the performance improved in proportion to the increase in the first anoxic fraction, being most stable at the highest anoxic fraction of the cycle length (0.33). Copyright © Taylor & Francis Group, LLC.en_US
dc.identifier.citationJournal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering. Vol.43, No.7 (2008), 725-730en_US
dc.identifier.doi10.1080/10934520801959880en_US
dc.identifier.issn15324117en_US
dc.identifier.issn10934529en_US
dc.identifier.other2-s2.0-42649117846en_US
dc.identifier.urihttps://repository.li.mahidol.ac.th/handle/20.500.14594/19233
dc.rightsMahidol Universityen_US
dc.rights.holderSCOPUSen_US
dc.source.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=42649117846&origin=inwarden_US
dc.subjectEnvironmental Scienceen_US
dc.titleThe influence of organic loading and anoxic/oxic times on the removal of carbon, nitrogen and phosphorus from a wastewater treated in a sequencing batch reactoren_US
dc.typeArticleen_US
dspace.entity.typePublication
mu.datasource.scopushttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=42649117846&origin=inwarden_US

Files

Collections